TRANSFORMERComplete units

Oil-Immersed Transformers

Three-phase oil-immersed transformers supplied through qualified manufacturing partners to the agreed HV / LV ratings, vector group and site conditions.

  • ONAN / ONAF
  • 50 / 60 Hz
  • Cu / Al windings
Hermetically sealed oil-immersed distribution transformer
Hermetically sealed, corrugated-tank distribution transformer.

01 / Specification

Transformer specification

Construction
Three-phase, core type, oil-immersed
Cooling
ONAN; ONAF where the rating requires it
Tank
Hermetically sealed corrugated tank or conservator tank
Windings
Copper or aluminium conductors
Voltage regulation
Off-circuit tap changer; on-load tap changer by project
Frequency · connection
50 / 60 Hz · Dyn11, Yyn0 or as specified

Rated power, HV / LV voltages, impedance, losses and accessories are defined per project and confirmed in the technical offer. Design basis: IEC 60076 or the specified project standard.

02 / Configuration

Tank and cooling

Hermetically sealed transformer with corrugated tank walls

ATank design

Hermetically sealed

Corrugated tank walls take up the oil expansion. No conservator and no air contact with the oil, so routine maintenance stays minimal.

Typical use: distribution networks and compact substations.

Oil-immersed transformer with conservator tank

BTank design

Conservator type

An expansion tank holds the oil-level changes, with a breather and gas-relay protection. Preferred where oil sampling and monitoring are specified.

Typical use: industrial and utility substations.

ONANNatural cooling

Oil natural, air natural. Corrugated fins or radiators dissipate the losses without auxiliary power.

ONAFForced-air cooling

Fans on the radiators add a second rating stage for the same active part. Fan supply and control are defined per project.

03 / Build

From core to finished unit

Illustration of a three-limb transformer core with step-lap joints
Illustrative drawing: three-limb stacked core with multi-step-lap joints

Build stage

Magnetic core

CRGO laminations are stacked to the lamination schedule and clamped before the windings are fitted.

Core steel grade and loss basis stated in the offer.

Oil-immersed transformer cores ↗

Transformer active part with cover and HV and LV bushings
Active part with cover, HV and LV bushings

Build stage

Active part

Windings, leads and tap changer are assembled on the core and connected to the cover fittings.

Bushing arrangement and cover layout to the approved drawing.

Vacuum drying and oil-processing equipment for transformer insulation
Vacuum drying and oil-processing equipment

Build stage

Drying and oil filling

The active part is dried and the tank is filled with transformer oil under vacuum to remove moisture and air from the insulation.

Insulating liquid by specification.

04 / Testing

Routine tests before dispatch

  1. 01Winding resistanceMeasured on each winding and corrected to reference temperature.
  2. 02Voltage ratio and vector groupRatio checked on the tap positions; phase displacement verified.
  3. 03Impedance and load lossShort-circuit impedance and load loss at rated current.
  4. 04No-load loss and currentMeasured at rated voltage and frequency.
  5. 05Dielectric testsSeparate-source AC and induced-voltage withstand.
  6. 06Tank and oilLeak test on the filled tank; breakdown voltage of the oil.

Routine tests to IEC 60076-1 unless the project standard differs. Type tests, special tests and witnessed testing are agreed at order.

05 / Project definition

Define the transformer before the offer

Typical applications

  • Utility and industrial distribution
  • Plant and site substations
  • Renewable-energy collection
  • Infrastructure and building supply

Specification checklist

Rated power, HV / LV voltages, frequency, vector group, impedance, cooling, tank type, tap changer, loss requirement, installation altitude and destination.

Before ordering

Can you supply transformers to a specified loss requirement?

Yes. State the no-load and load loss values, or the efficiency regulation that applies, with the enquiry. The design is confirmed against them in the technical offer.

Copper or aluminium windings?

Both are available. Copper gives a more compact active part; aluminium lowers the material cost. The choice is confirmed together with the loss and dimension requirements.

Sealed tank or conservator?

Sealed tanks suit distribution duty with minimal maintenance. Conservator tanks suit larger ratings and sites that specify oil sampling and gas-relay protection.

Which documents come with the transformer?

The general arrangement drawing, nameplate data and routine test report are typical. Further documents are agreed per order.

RFQTechnical review

Send your transformer specification

Include rated power, HV / LV voltages, vector group, cooling and destination.