Reconstruct concealed laps with layer identity, a registered circumferential reference and evidence of strip-end placement. Record both ends and the overlap extent in the stated assembly condition so the closure map identifies the packet and station requiring investigation.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
Label each closure location as programmed, reconstructed or observed, and retain the geometry and placement evidence behind it. Use that distinction when the joint becomes concealed by later layers.
Start with the actual construction route
Distinguish single-turn cut laminations, groups of laminations, packets and a genuinely continuous spiral. Their identities and end relationships are different. A formula for one cut strip making one complete turn cannot automatically reconstruct every turn of an uncut continuous strip.
Record the actual construction route, including every operation that changes the order or closure location of a lamination. For a cut-and-reassembled route, preserve part identity through grouping, nesting, forming and final closure.
The reconstruction method below uses a defined single-turn lap construction and an explicit layer-identity record. Adapt its identity rules to the actual process rather than relabeling every physical group as one layer.
Define a coordinate that survives closure
Choose a physical zero station, a direction of increasing arc length and a particular reference contour for each layer. Preserve marks or registered fixture references that can recover those choices. Record whether the map describes the circular nesting state, the formed rectangular state or the final restrained assembly.
For a rectangular contour, use distance along the defined path. An angular coordinate measured from the window center does not increase uniformly with arc length around straight sides and corners. A normalized path coordinate q = s/C, where C is that layer’s complete path length, provides a convenient 0-to-1 display. Equal q values on different layer shapes still need a mapping to actual physical stations.
The displayed zero and one represent the same circumferential station. Keep this periodic boundary visible when assessing concentrations; otherwise, a compact group around the datum may appear to be two remote groups.
Recover both ends, not an unnamed joint point
For a simplified single cut lamination, let C_i be its defined one-turn path length, L_i its effective placed length and s_i its leading-end position along that path. Assume no extension, no subsequent slip, and exactly one complete turn plus an overlap smaller than C_i.
The overlap is o_i = L_i − C_i. The trailing-end coordinate is (s_i + L_i) mod C_i, equivalently (s_i + o_i) mod C_i. A chosen overlap-center marker is q_i = [(s_i + o_i/2) mod C_i]/C_i.
These equations expose the missing input. L_i and C_i determine overlap length, but s_i determines where that overlap lies. A nesting relationship may predict s_i from preceding groups; it remains a process-model prediction until anchored to placement evidence.
For assumed C_i = 1000 mm, L_i = 1012 mm and s_i = 996 mm, the overlap is 12 mm. Its trailing end wraps to 8 mm, and its center wraps to 2 mm, giving q_i = 0.002. With the same two lengths but s_i = 400 mm, the center is 406 mm, or q_i = 0.406. Equal length and equal overlap have produced very different closure locations.

A negative L_i − C_i is outside this lap model; it requires a gap or another construction interpretation. More than one complete turn likewise requires another model. Do not conceal those cases by applying a modulo operation and reporting a plausible-looking position.
Check clustering across the datum
Plot layer or group identity vertically and normalized position horizontally. Preserve packet boundaries and show the two ends when overlap extent matters. A center marker is a summary, not a substitute for the full overlap interval.
The diagram’s assumed markers at q = 0.96, 0.98, 0.00, 0.02 and 0.04 form one group near the common zero/one station. Ordinary subtraction would place 0.98 and 0.02 far apart; their shortest normalized separation is min(0.96, 1 − 0.96) = 0.04. This periodic-distance calculation is geometric, not a magnetic crowding limit.
Assess the pattern against its approved physical joint region. A concentration is not automatically a defect: it may be intentional. Conversely, an apparently regular plotted sequence can be wrong if its datum, layer order or formation-state mapping is wrong. Set the cluster-width criterion from the approved joint geometry.
Preserve the evidence before it becomes hidden
Retain the released program revision, commanded lengths, independently established effective lengths where available, material and layer/group identities, nesting reference, and registered placement observations at selected boundaries. Photographs need scale, datum and a link to the actual group being recorded.
Mark each map entry by its evidence class. A planned point comes from the approved program. A reconstructed point comes from stated geometry and placement assumptions. An observed point has a defined inspection method and assembly state. If a layer is inferred from its neighbors rather than checked, preserve that fact.
Forming, opening, reclosing and restraint changes can move the relationship after the original record. Keep the history and any additional observations with the same map. Do not claim an earlier photograph verifies a later concealed state without evidence that the relevant location survived.
Use the map to narrow an investigation
Loizos and colleagues report longitudinal flux measurements at limb, yoke and corner and normal flux around a wound-core step-lap region. These localized observations support keeping joint position in the manufacturing record. [2]
Use the closure map to select the packet, station or process transition for further inspection when magnetic response changes. Release the joint against approved geometry, registered observations and magnetic tests at the correct assembly boundary.
Compare overlap location with the steel-count scale
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume 100 layers and a 12.0 mm overlap per layer in the coordinate example. Nominal steel thickness is 23.00 mm. If those ideal overlap regions all coincide, they add another 100 × 0.23 = 23.00 mm of local steel-thickness count; if separated among five nonoverlapping stations of 20 layers each, each station gains 4.60 mm. This geometric comparison explains why closure location must accompany overlap length. Check the real stagger and seating rather than accepting equal total strip demand.
Manufacturing controls. Control layer identity, strip length, overlap registration, winding slip and the retained joint sequence through forming. Local wound-core flux depends on the region and layer position, so qualify the final mapped joint. [2]
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] G. Loizos, T. Kefalas, A. Kladas, T. Souflaris and D. Paparigas, Flux distribution in single phase, Si–Fe, wound transformer cores, 2008, DOI 10.1016/j.jmmm.2008.04.068.