Register local flux waveforms at the corner, yoke and limb of selected wound-core paths. Compare those locations under the same excitation and process state to identify the region that controls the magnetic design.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
Answer that question with a registered local measurement map. A bright corner on an unvalidated simulation, or a forming-radius calculation by itself, cannot establish the local flux density of a finished assembly.
Evaluate corner flux through the complete magnetic path
The inside and outside sheets follow different complete magnetic paths. At a corner, they also differ in curvature and mechanical history. Shorter path length provides a reason to investigate preferential inner-path magnetization, but it does not establish a universal B proportional to 1/r relationship for a rectangular wound core.
That expression treats a selected circular arc as though it were the complete magnetic circuit. A rectangular core includes straight limbs, yokes, transitions, joints where present, and interactions between sheets. The material is anisotropic and nonlinear; stress can alter its response. The local result must satisfy the complete field problem and the imposed excitation.
In particular, a lower reading in the innermost sheet does not automatically disprove geometric redistribution. Leakage, local material condition or measurement placement may affect that sheet differently from its neighbors. Preserve exceptions instead of forcing every result into a monotonic radius rule.
What an original wound-core experiment establishes
Loizos and colleagues report measured longitudinal flux at the limb, yoke and corner of a wound transformer core, together with normal flux around the step-lap region. Their abstract reports higher flux toward the inner window side and variation between regions. Use that evidence to define the measurement map rather than assuming one radius law applies everywhere. [2]
These observations justify measuring the actual local distribution rather than assigning one crowding factor to a different geometry, steel grade or assembly. Compare locations at matched excitation and record the mechanical and thermal history.
Use this evidence to justify a measurement plan, not to copy a peak value into a new design. A whole-core loss measurement answers a different question from a local sheet-flux observation.
Register a corner, a yoke and a limb on the same paths
For an instrumented development core, identify selected inner, intermediate and outer sheets or otherwise defined packets before closure. Register their positions at a straight limb, a straight yoke and a corner. Keep the location convention stable through forming and any subsequent processing.
A useful record links each channel to the layer identity, station, sensor orientation, effective enclosed area, turn count and polarity. If a coil surrounds several sheets, the result is an average over that enclosed iron and associated flux paths. It cannot resolve the peak in a single sheet without additional information.
Sensor installation can change spacing or stress. Use an approved development construction and compare geometry and global magnetic response before and after installation. Qualify the sensor arrangement before relying on its local readings.

Comparing corner and straight-station channels on a registered path helps distinguish a local location effect from a general inner-to-outer pattern. Repeat across excitation levels; a distribution measured at a modest level need not remain proportional near local saturation.
Convert voltage into a defined flux change
CERN’s Fabrication and calibration of search coils, by Marco Buzio, explains the search-coil principle and the role of geometry, orientation and integration. For a stationary coil with N_s equivalent turns and a defined enclosed area A_s, the measured voltage is related to the change in linked flux. Under the simplifying assumption that the relevant field component can be represented by its area average:
ΔB_average = −∫v(t)dt / (N_s A_s).
For an illustrative two-turn coil enclosing an assumed effective area of 10 mm², an integrated voltage of −20 microvolt-seconds corresponds to a +1.0 T change in that average component. The calculation uses 10 mm² = 10 × 10⁻⁶ m². It is a unit check, not a recorded transformer result or a predicted corner peak.
The integration gives a change from a starting state. Recovering an absolute periodic waveform requires a justified reference or periodicity procedure. Arbitrarily setting a constant to zero can conceal a remanent component. Voltage offset produces integration drift, and a wrongly assigned turn count or area scales every derived result.
Retain the raw voltage, sampling and bandwidth information, offset treatment, excitation reference and area calibration. At a curved station, do not assume that a convenient projected drawing area is the coil’s effective flux area. The signal is an enclosed-flux measurement rather than a point probe.
Separate a geometry question from a material-state question
Suppose the corner/limb relationship changes after processing. That observation alone cannot say whether the corner geometry changed, a stressed region recovered, a joint moved or the sensor registration shifted. Inspect the physical paths before interpreting the magnetic difference.
An author-proposed comparison uses the same registered geometry and excitation while documenting material and process state. A complementary comparison varies the geometry while holding the material route as closely matched as practical. Neither comparison is automatically clean: forming changes mechanical history, and thermal processing can change shape or coating condition. Record those limitations explicitly.
A credible field model should reproduce the observed spatial pattern within measurement uncertainty using the actual geometry, material description and excitation. Fitting a single global loss value does not validate its corner distribution. Conversely, local B measurements alone do not supply a complete local loss map; loss requires additional constitutive and waveform information.
Make the design decision from the registered evidence
Use the map to identify where another measurement or geometry refinement is warranted. Carry the local waveform, material state and sensor uncertainty into that decision. A tighter corner may deserve attention, but an inner-radius limit without those conditions is not a demonstrated magnetic qualification.
Deliver each flux waveform with its layer identity, physical station, effective sensor area and measurement uncertainty. Use that registered evidence to select the next geometry refinement or material-state comparison.
Calculate the search-coil signal from an identified steel section
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume a search coil encloses 100 layers over 20.0 mm strip width, with flux normal to their combined steel section. Net nominal steel area is 100 × 0.23 × 20 = 460 mm². At assumed sinusoidal peak induction 1.7 T and 50 Hz, a two-turn coil produces E_rms = 4.44288 × 50 × 2 × 1.7 × 460 × 10⁻⁶ = 0.347433 V. Use that nominal signal to select the acquisition range, then integrate the measured voltage using the verified enclosed area. [2]
Manufacturing controls. Control layer count, sensor encirclement, rolling direction, corner radius, forming strain and the applied voltage waveform. Register each sensor to the same limb, yoke or corner path before comparing local flux.
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] G. Loizos, T. Kefalas, A. Kladas, T. Souflaris and D. Paparigas, Flux distribution in single phase, Si–Fe, wound transformer cores, 2008, DOI 10.1016/j.jmmm.2008.04.068.