Map every triangular wound-core frame to the two completed limbs it contributes to. For the construction reviewed here, neighboring frame portions combine at each limb, so component geometry and magnetic response must be matched through that shared assembly.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
Matching therefore needs a component-to-limb map. Equal outside dimensions, three similar-looking rings or a circular assembled column do not establish equal net iron area, magnetic path or material response.
Name the frame before naming the phase limb
Label the wound limbs A, B and C. Label the closed frames AB, BC and CA according to the two limbs they span. The assembly map is:
| Completed limb | Contributing frame portions |
|---|---|
| A | AB at A, plus CA at A |
| B | AB at B, plus BC at B |
| C | BC at C, plus CA at C |
The triangular arrangement describes the positions of three parallel wound limbs. A projected triangle is not the actual length of a complete magnetic loop. A frame also includes its two vertical portions, upper and lower connecting portions, corners and any closure features.
Define each frame portion by its actual construction and the completed limb to which it contributes. Where a frame contains several subrings, preserve the subring-to-frame and frame-to-limb relationships in the assembly record.
The three-frame construction considered here pairs neighboring frame portions into completed columns. Treat its topology as the declared geometry for the calculations below; derive the steel area from the actual sections.
Add the iron areas that actually meet at a limb
Use net magnetic area for each contributing portion at a defined transverse section. The two portions must be referred to the same section plane and correct assembly state. Gross outline area includes spaces and nonmagnetic material; it is not automatically the sum of net iron areas.
In the simplest uniform-section construction, let the frames’ net areas be a_AB, a_BC and a_CA. If each frame has the same net area at both of its limb portions, the completed areas are:
A_A = a_AB + a_CA; A_B = a_AB + a_BC; A_C = a_BC + a_CA.
For assumed a_AB = 100 cm², a_BC = 98 cm² and a_CA = 102 cm², the completed limb areas are 202, 198 and 200 cm². Their mean is 200 cm² and their maximum-to-minimum spread is 4 cm², or 2% of that mean. These are illustrative areas, not measured tolerances or a prediction of excitation-current imbalance.

For a frame with differently shaped or differently sized portions, use separate entries a_AB,A and a_AB,B rather than forcing one a_AB into both positions. A subring arrangement may require several entries within each frame portion. The completed outline can remain nearly circular even when the contributing net areas or material distributions differ.
Equal total column area does not finish the matching job
A completed limb’s area is useful for an overall flux-density estimate only with a defined total axial flux and average-area interpretation. It does not establish that neighboring frame portions share that flux equally. Local densities belong to their own portions and paths.
Similarly, equal perimeter is only one ingredient of magnetic matching. In a simplified linear scalar model, a uniform path has reluctance proportional to l/(mu A). A longer path, a smaller area or a different permeability can change that model’s response. For a path with variable area and properties, the corresponding integral depends on those variations around the loop.
A real grain-oriented wound assembly adds anisotropy, nonlinear magnetization, mechanical history and potentially closure effects. No single measured perimeter or outline diameter captures them all. Keep these model expressions as diagnostic reasoning rather than a release formula for a finished transformer.
Most importantly, retain the coupling: the winding around a completed limb interacts with both contributing frame portions. Assigning one independent phase inductance to each ring can remove the relationship that the matching investigation needs to examine.
Keep independent causes of asymmetry separate
Build the comparison in four parts. First, document geometry: net sections, relevant path lengths, corner shapes and relative frame placement. Second, document material identity and orientation, including which subrings use which source strips. Third, document process state: forming, thermal treatment, closure and restraint. Fourth, document the assembled electrical boundary and measurement history.
These parts can produce similar terminal symptoms for different reasons. A larger exciting current on one phase is not proof that one ring is longer. A swapped winding polarity or unequal applied waveform can imitate a core difference. A restraint change can alter local material behavior while leaving a convenient outside dimension almost unchanged.
Use a consistent ring-to-limb map through every record. If a frame is replaced or rotated, update the correspondence before comparing measurements. An old component identifier attached to a new physical position can create an apparent imbalance that is only a traceability error.
Compare rings and the assembled core at their own boundaries
Where development access permits, retain component geometry and magnetic observations before assembly under defined conditions. Then compare the completed assembly under a documented common excitation case. A component observation and an assembled phase observation are related evidence, but they are not interchangeable acceptance values.
The matching record must include frame identity, subring identity where applicable, both limb contributions, measurement state, excitation conditions and the permitted assembly orientation. Set the acceptance criteria from the actual design and verification results.
Keep each phase limb linked to both contributing frame paths, their material identities and assembled test state. Use that map to trace an observed asymmetry to geometry, process condition or electrical configuration before changing the assembly.
Match the three limbs on net steel area
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume each frame portion is 100 mm wide with 400 layers of the catalog gauge. Each contributes 100 × 400 × 0.23 = 9,200 mm² of nominal steel area; two portions give 18,400 mm² per completed limb. If one portion contains only 399 layers, its two adjacent completed limbs each lose 23 mm², or 0.125% of their nominal area. Identify the affected frame before interpreting an assembled phase difference.
Manufacturing controls. Control frame layer count, width, gauge allocation, local curvature, assembly fit and restraint. Preserve rolling-direction geometry and grade identity through the frame-to-limb map. [2]
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] T. Takamiya, K. Hanazawa and T. Suzuki, Recent Development of Grain-Oriented Electrical Steel in JFE Steel, JFE Technical Report No. 21, 2016, Section 2.2.