Temporary Assembly Shims: Proving Removal Without Losing Final Geometry

  • Chenfan Power

Temporary-shim removal closes two acceptance questions: where every temporary item went, and how the assembly sits after those items stop carrying or locating it. A tray of four returned shims answers the inventory question; the final support state and measured geometry complete the release evidence.

Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.

Define the removal sequence, core-joint limits and support-transfer arrangement in the released assembly design and manufacturing process. Use the verification framework below to track temporary items and measure the assembly in that specified final state.

Identify the function before counting the part

Label each temporary shim or spacer by identity, location and intended function. A setting shim establishes position; a temporary support carries load; an access spacer preserves working clearance. One item can perform more than one function. Calling everything a “packing piece” conceals what must replace its function when it leaves.

Keep permanent parts in a separate classification. A permanent insulating spacer should not disappear from the drawing simply because it resembles a temporary setting piece. Record whether a temporary item is an intact reusable part, a sacrificial piece or a cut-to-fit item that can generate fragments. For reusable pieces, return identity and condition matter as well as quantity.

An assembly aid can provide a temporary support function that must be taken over by a retained component before removal. Describe that transfer explicitly and verify the final support state rather than assuming the part disappears without changing geometry.

Record three mechanical states

Define the state in which each dimension is meaningful. “After removal” can still mean that an external fixture is holding the assembly in position.

StateSupport description to recordEvidence that remains conditional
S0: before removalTemporary parts, retained parts and external fixture contacts presentGeometry still includes temporary restraint
S1: temporary parts removedRetained supports and any external restraints still activeInventory can close, but fixture-held geometry may differ from release geometry
S2: specified final stateThe support and fastening condition required for dimensional acceptanceFinal geometry is evaluated against its stated basis

S2 need not mean that every external support has been removed. It means the particular state required by the drawing and inspection plan. If the final assembly is intended to sit on permanent supports, those supports belong in the description. Record fastening condition, orientation, datum references and relevant temperature alongside the measurement.

The mechanical review should explain where the former support reaction goes. The retained load path may include a clamp, carrier, seat or insulating component. A local dimension measured while a temporary support is carrying load cannot establish the result after that load is redistributed. Nor does shim thickness alone predict the change: seating, clearances and elastic deformation can contribute.

Three assembly support states and a two-axis matrix separating shim accountability from final geometry
Original state-and-decision diagram. S2 is the specified acceptance state, not automatically an unsupported assembly. The numerical interface example is assumed and is not a core joint-gap limit.

Close accountability without confusing it with geometry

Use a controlled temporary-item register: unique identity, insertion location, removal event, condition on return and reconciliation of fragments or missing pieces. Close the register independently of the final dimensional inspection.

The transferable idea is to reconcile what entered the work area with what was removed, retained by design or otherwise disposed of. For an assembly-specific shim record, list the expected temporary identities, their insertion locations, their removal status and the disposition of any fragments. A photograph can corroborate the location and condition but should not silently substitute for inaccessible-area verification.

Equal totals are weak evidence if parts can be substituted or broken. Four pieces returned against four pieces issued does not prove that the four intended items have left the assembly. A chipped shim can return to its tray while a fragment remains elsewhere. An unresolved item should remain explicitly unresolved; an acceptable dimensional result does not explain its location.

A conditional example with two independent outcomes

Consider four assumed temporary items, T1–T4, and three specified inspection locations on a fixture-to-carrier interface. For this example only, assume that the approved final-state interface criterion would require each gap to be at most 0.20 mm. This number is a teaching assumption, not a core joint-gap limit or a recommended acceptance value. Ignore measurement uncertainty in the arithmetic example; a real decision needs its agreed uncertainty and decision rule.

Illustrative caseAccountability resultFinal-state gaps, mmIndependent outcome
AT1–T4 returned intact and reconciled0.12, 0.15, 0.24Inventory closes; geometry fails at location 3
BT1–T3 reconciled; T4 unresolved0.12, 0.15, 0.18Geometry passes the assumed criterion; accountability remains open

In Case A, the largest gap exceeds the assumed limit by 0.04 mm. Counting cannot remove that excess. In Case B, the largest gap is 0.02 mm below the assumed limit, but that arithmetic provides no evidence about T4. Neither case supports release on these two checks alone.

These results do not identify a root cause. A changed gap could arise from seating, the retained support arrangement or the measurement setup. Investigate against the defined states rather than assuming that inserting another shim restores the released design.

Make the final record describe the delivered condition

An effective completion record connects the temporary-item ledger to the final-state measurements. It identifies which earlier dimensions were superseded, which locations were rechecked and whether the retained support configuration matches the approved design. Preserve inaccessible-location exceptions and unresolved dispositions instead of hiding them behind “all shims removed.”

Release requires both accountable temporary-item disposition and acceptable final-state geometry, alongside the other required checks. Keep the item ledger, final measurements and approved retained load path together so the release record shows how the assembly reached its specified condition.

Challenge the removal check with one steel sheet

Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] In the assumed 0.20 mm interface-gap criterion above, one nominal 0.23 mm steel sheet left across a fully seated contact would impose at least 0.23 mm separation in a rigid, uncompressed screen. It exceeds the criterion by 0.03 mm. A fixture that masks that separation can pass an inventory count while preserving an assembly error. Inspect the specified released interface after removing the assembly aid, then reconcile the temporary-item list independently.

Manufacturing controls. Control temporary-part identity, contact location, support transfer, restraint sequence and final datum seating. The actual loaded stack can deform, so verify the final interface rather than relying on the rigid screen.

Laminated-stack experiments identify contact and modal behaviour for particular steel, surface and clamping configurations. Use representative assembly evidence when those contact properties control this decision. [2]

References

[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.

[2] M. Pirnat, G. Čepon and M. Boltežar, Introduction of the linear contact model in the dynamic model of laminated structure dynamics: an experimental and numerical identification, 2013, DOI 10.1016/j.mechmachtheory.2013.02.003.