Separating Fixture Modes from Core Modes in Factory Vibration Tests

  • Chenfan Power

A core-assembly resonance reflects the core, carrier and test support acting together. Measure the motion at each relevant coordinate and compare the corresponding mode shapes when the fixture boundary changes. That evidence identifies how strongly the fixture participates in the measured response.

Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.

“The peak moved, so it was a fixture mode” is an incomplete conclusion. A coupled mode contains motion in both structures. Its frequency can respond to a fixture change while its core displacement remains important. A controlled comparison needs reference points on both sides of the interface and corresponding mode shapes, rather than two lists of spectral peaks.

Define the structure whose modes are being identified

State whether the test is intended to characterize the supported assembly, approximate an isolated core assembly or validate a particular production mounting arrangement. These objectives require different boundary conditions. A carrier used for convenience should not silently become part of the modeled product.

Distinguish a spectrum recorded during operation from a frequency-response function constructed from measured excitation and response. A coupled modal study should include the fixture coordinates and fit the observed frequencies and mode shapes; stack contact and preload affect that response. [2]

The primer also describes a particular minibus-body test using elastic suspension to approximate free-free conditions. That example establishes the importance of a deliberate test boundary; it is not a suspension prescription for a heavy laminated core. A core fixture comparison must preserve the approved support and handling requirements.

Record the fixture geometry, contacts, fastening state, assembly orientation, test amplitude, relevant temperature and sensor mounting. If the fixture substitution also changes core clamp preload, the comparison is no longer an isolated change to the external boundary. Maintain or separately characterize those changes before interpreting the difference.

Put measurement coordinates on the fixture as well as the assembly

Define a common coordinate map for each configuration. Include response locations on the core assembly, retained carrier and test fixture, with directions and polarity. The fixture reference should represent a relevant structural motion; a point on the floor does not automatically describe an upper fixture member that bends.

Use compatible force and response measurements to build the required FRFs. Record whether each comparison uses the same physical input location and direction. Raw response amplitudes from different input forces cannot be treated as equal modal evidence merely because the analyzer settings match.

The primer shows that a modal residue depends on the product of the modal displacements at the input and response coordinates. A coordinate close to a modal node can therefore make a mode weak or absent in that FRF. Absence at one reference point does not prove absence from the structure. Check alternative input or reference coordinates where necessary to cover the modes of interest, and retain the geometry and phase information needed to relate the measurements.

Sensor loading and mount compliance can also change a response. This is especially relevant for a thin fixture element or a small local component. The source explicitly warns that transducer loading and changing environmental conditions can violate the assumption of an unchanged structure during a test.

Two-coordinate core-like and fixture spring model with four calculated eigenfrequency and shape-ratio rows
Original two-coordinate model and calculated comparison. Only the fixture-to-ground spring changes. Frequencies and shape ratios are hypothetical; shape normalization is arbitrary and gives no operating vibration amplitude.

A two-coordinate counterexample to simple peak labeling

Consider an original, undamped linear teaching model with one core-like coordinate xc and one fixture coordinate xf. The labels identify the modeled masses, not actual factory equipment. A coupling spring kc joins them; a spring kf connects the fixture mass to a rigid ground. There is no separate core-to-ground spring.

Assume mc = 2 kg, mf = 1 kg and kc = 2.00 MN/m. Compare kf = 1.00 MN/m with kf = 4.00 MN/m, holding every other parameter fixed. For q = [xc, xf], the mass matrix is diagonal with entries mc and mf, and the stiffness matrix has rows [kc, −kc] and [−kc, kc + kf].

The undamped eigenvalues λ = ω² satisfy:

mc mf λ² − [kc mf + mc(kc + kf)] λ + kc kf = 0

The first equation gives the relative shape coordinate:

xf / xc = (kc − mc λ) / kc

Normalize xc to 1 for each mode; this normalization is arbitrary and does not represent a measured vibration amplitude.

Assumed fixture stiffnessModeCalculated frequency, HzShape ratio xf/xc
1.00 MN/mLower82.38+0.732
1.00 MN/mUpper307.46−2.732
4.00 MN/mLower126.10+0.372
4.00 MN/mUpper401.76−5.372

Both frequencies change when only fixture stiffness changes. Both modes include nonzero motion of both masses. The positive ratios describe motion in the same direction; the negative ratios describe opposing motion. The upper-mode fixture-to-core ratio increases in magnitude, but this does not eliminate the core coordinate from that mode.

These are exact eigenfrequencies of the declared ideal model, not measured peaks. Damping, nonlinear contacts, multiple core deformation patterns and sensor effects are omitted. The calculation predicts neither a real core resonance nor its operating response amplitude.

Compare corresponding shapes and retain unresolved assignments

For an actual comparison, first fit modal parameters within the verified frequency range and examine the spatial patterns. Compare corresponding core and fixture coordinates, relative phase and the confidence of the identification. Frequency order alone is weak correspondence evidence: nearby modes can change order or mix as the support changes.

A mode showing dominant fixture motion and strong sensitivity to the fixture is evidence of fixture participation. A mode with substantial core deformation and support sensitivity is better described as a coupled assembly mode. If the chosen coordinates cannot resolve the pattern, leave the classification unresolved instead of assigning it by peak height.

An empty-fixture test can help identify candidate fixture features. Its boundary and loading differ from the loaded test, so numerical coincidence is supporting evidence rather than proof of identity. Likewise, a repeat test on the same fixture assesses reproducibility but does not establish independence from that fixture.

Report the controlled fixture differences, coordinate map, corresponding mode shapes and identification limits. Assign each resolved mode to the behavior it represents in the intended assembly model, and keep unresolved assignments visible for the next measurement.

Recalculate fixture sensitivity with a traceable steel mass

Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume a packet of 500 rectangular sheets, each 300 × 500 mm. Its nominal steel mass is 131.9625 kg. In a separate single-coordinate screening model with assumed support stiffness 20.0 MN/m, f = √(k/m)/(2π) = 61.96 Hz. Doubling that stiffness gives 87.62 Hz, a 41.42% increase at unchanged mass. This substantial support sensitivity is a reason to identify the coupled fixture response before assigning an operating peak to the core.

Manufacturing controls. Control packet count, coating/contact state, clamp preload, support positions and fixture attachment. Identify frequencies and shapes across a representative preload and support range; laminated contact properties are configuration-dependent. [2]

References

[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.

[2] M. Pirnat, G. Čepon and M. Boltežar, Introduction of the linear contact model in the dynamic model of laminated structure dynamics: an experimental and numerical identification, 2013, DOI 10.1016/j.mechmachtheory.2013.02.003.

Chenfan Electric

Direct coordination

Start a conversation.

A drawing, a material requirement, or a project to discuss.