A core assembly seats consistently when its locators constrain the intended motions without fighting one another. Check the active contact directions and the assembly’s response to clamping and temperature changes; a count of stops, pins or screws alone misses those interactions.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
Apply that check to a defined object. A rigid carrier can be assessed with six rigid-body degrees of freedom; a laminated packet has internal motions that this count does not capture. A well-located carrier is not proof that every lamination is aligned.
Separate location from the force that maintains contact
A locator defines a position through its contact geometry. A clamp applies the force needed for the intended seated state. A component can perform both functions, but the drawing should identify both rather than counting every force-applying screw as an independent datum.
For ideal rigid-body location, only independent constraint equations add rank. Review contact deformation, load direction and thermal movement separately from that kinematic rank; the laminated packet introduces its own compliance. [2]
List the contacts intended to engage and their normals. State which retention or preload keeps them engaged. An ideal frictionless normal contact constrains one local normal motion while seated; unspecified friction should not silently supply missing location. A contact which opens no longer provides its assumed compressive constraint.
Derive the rows rather than relying on “three-two-one”
For a small rigid displacement, let u = (u_x,u_y,u_z) and θ = (θ_x,θ_y,θ_z). A point at r moves by u + θ × r. An active ideal contact with normal n has the incremental condition:
n · (u + θ × r) = 0.
A constraint table can then reveal whether the rows are independent. Consider an original ideal carrier example with nonzero distances a and b. Coordinates refer to a declared corner origin; normal directions identify the relevant face contact.
| Contact | Position and normal | Incremental condition | Motion resolved with preceding rows |
|---|---|---|---|
| P_1 | (0,0,0), z | u_z = 0 | z translation |
| P_2 | (a,0,0), z | u_z − aθ_y = 0 | y rotation |
| P_3 | (0,b,0), z | u_z + bθ_x = 0 | x rotation |
| P_4 | (0,0,0), y | u_y = 0 | y translation |
| P_5 | (a,0,0), y | u_y + aθ_z = 0 | z rotation |
| P_6 | (0,0,0), x | u_x = 0 | x translation |
For a and b nonzero, these six ideal equations have rank six. That establishes the local rigid-body constraint count for this model. It does not establish allowable contact pressure, positioning accuracy, fixture stiffness or internal packet restraint.
The points sharing the ideal origin represent differently oriented face contacts, not three interchangeable constraints along one normal. Relocating real contacts changes their moment arms; the actual positions and normals belong in the real table.

A seventh contact can add load without adding a degree of constraint
Add a second x-normal end stop at (a,0,0). Its ideal rigid-body row is again u_x = 0, because θ × (a,0,0) has no x component. It repeats the P_6 row rather than increasing rank.
That redundancy matters when the two physical stops disagree about length or position. The rigid model may show two equivalent rows, while actual contact compression, fixture bending or workpiece deformation resolves the conflict through force. Six-dimensional rank is therefore a kinematic screen, not a complete stressed-assembly solution.
Extra contacts are not always unacceptable. A design can deliberately use compliance or elastic averaging to achieve its load and location functions. If it does, specify the compliance and assess its effects; do not describe a conflicting collection of nominally hard stops as an exact constraint merely because it has enough contacts.
Screen thermal accommodation with a separate deformation model
Rigid-body kinematics alone cannot represent thermal length growth. For an entirely hypothetical uniform carrier, assume L = 500 mm, expansion coefficient α = 12 × 10⁻⁶/K and temperature rise ΔT = 40 K. Free growth is:
ΔL = αLΔT = 0.24 mm.
Two immovable opposing end stops set to the original length cannot both accommodate that free increase without a change in contact, compliance or deformation. This example does not prescribe a clearance or predict force in a real core fixture.
For a separate ideal uniform elastic rod with E = 200 GPa and complete axial restraint, the thermal compressive stress magnitude would be EαΔT = 96 MPa. This is an assumed rod limit case, not a calculated stress in a laminated core, carrier contact or fixture. Real supports can move, deform, lose contact or redistribute force.
Use the actual material, temperature distribution and fixture boundary to determine whether accommodation is required. A released direction, sliding feature or compliant element must preserve the intended location and load path under that design’s conditions.
Verify the seated and released states
The proposed evidence should connect locator geometry to contact engagement and the resulting assembly position. Compare the relevant datum relationships while seated and after the approved release or support change. A dimension achieved only by forcing the assembly against conflicting stops can change on release.
Retain contact positions/normals, clamp function, temperature state, any intentionally compliant direction and the internal packet restraints assessed separately. Use representative position and contact observations with their measurement uncertainty.
Release the assembly against a reproducible location and an acceptable loaded contact arrangement. Use the independent-constraint table to establish the locator geometry, then verify contact forces, deformation and lamination alignment in the actual assembly.
Keep locating geometry separate from packet growth
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume the carrier locates a 500-sheet packet through its build direction. Nominal steel thickness sums to 115.00 mm. An additional sheet raises it to 115.23 mm, consuming 0.23 mm of geometric accommodation before coating and seating are considered. If the assumed remaining locator clearance is 0.20 mm, the count error exceeds it by 0.03 mm. Correct the count or approved interface definition; forcing the packet between opposed stops changes the contact problem.
Manufacturing controls. Control independent locator directions, sheet count, loaded build, contact area and thermal accommodation. Use the carrier to locate the packet without assuming that the packet behaves as one rigid steel block. [2]
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] M. Pirnat, G. Čepon and M. Boltežar, Introduction of the linear contact model in the dynamic model of laminated structure dynamics: an experimental and numerical identification, 2013, DOI 10.1016/j.mechmachtheory.2013.02.003.