Qualify yoke-support pads for both the installed height and the dynamic response about their current preload. Record static settlement separately, then measure force, relative face displacement and phase under the relevant temperature and frequency conditions.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
Define the pad geometry, preload, temperature, environment and support condition before comparing data. “Soft” describes neither an acceptable final height nor a specified dynamic stiffness.
Define the static reference and settlement quantity
Record the free pad thickness, the loaded reference height and the time and temperature at which they were measured. Distinguish the initial load deformation from additional deformation after the reference state. If the same shortening is already included in the reference height, do not add it again as a separate allowance.
Static settlement under sustained load can alter the supported yoke position and its relationship to neighbouring restraints. In an assembly whose load can redistribute, individual pad force can also change. A constant total assembly weight does not prove constant load at every pad.
Define creep and dynamic response around the stated loaded reference. A change in static thickness does not determine the small-signal complex stiffness at a particular frequency; measure the selected pad around its actual working state.
Use the approved pad material and actual conditioning history. No creep percentage, service-life curve or permissible permanent settlement is transferred from that sheet into a yoke design.
Record dynamic response about the current working point
For a local linear harmonic representation, write pad displacement as δ_0 plus a small oscillation and force as F_0 plus its oscillatory response. At a stated frequency, a complex stiffness can be defined as:
k* = F_hat / δ_hat = k′ + i k″.
Using peak amplitudes, |k*| is force amplitude divided by displacement amplitude; k′ and k″ depend on the phase under the declared convention. The mechanical loss factor is k″/k′ in this simple representation. It is not an electrical dielectric-loss measurement.
Force should belong to the pad and displacement to its relative face motion. Fixture motion, support compliance, changing engagement or inertial force can contaminate an apparent force/displacement ratio. Retain how those contributions are measured or modelled.
Define creep and dynamic response around the stated loaded reference. A change in static thickness does not determine the small-signal complex stiffness at a particular frequency; measure the selected pad around its actual working state.
A static secant and a dynamic amplitude ratio are different
Consider an assumed pad example. A constant F_0 = 1000 N produces a reference deflection δ_0 = 1.00 mm. The static secant F_0/δ_0 is 1000 N/mm. That secant is not a measured tangent at the working point.
Suppose that, about this same reference state at an assumed 100 Hz, a displacement amplitude of 0.020 mm produces a force amplitude of 40 N, with force leading displacement by 20°. The assumed linear harmonic magnitude is |k*| = 2000 N/mm. Under the convention k* = |k*|(cosφ + i sinφ):
k′ = 1879.39 N/mm;
k″ = 684.04 N/mm;
k″/k′ = tan20° = 0.364.
All inputs are hypothetical. The example demonstrates that a static secant and a dynamic complex stiffness can differ; it supplies no actual yoke-pad property or acceptable damping value. Measuring only amplitude would not determine the real and imaginary components without the phase.
Now assume an additional 0.10 mm of settlement occurs under the same 1000 N after an unspecified interval. The later total deflection is 1.10 mm, giving a changed static secant of 909.09 N/mm. This arithmetic does not determine the later dynamic stiffness. That response must be assessed around the new state.

Keep component shape and contact with the data
For a pad, material modulus and component stiffness are different quantities. Loaded area, thickness, lateral expansion, bonding and contact conditions affect the conversion. Record loaded area and the available lateral expansion surfaces. Qualify component stiffness for the installed shape and boundary conditions.
Preserve the actual face constraint and pad footprint. A material tested in one shape and loading arrangement is not automatically representative of a thin pad under a partly engaged yoke seat. A loss of contact or edge concentration is an assembly condition, not a temperature correction to a material curve.
Use the applicable component specification and qualification evidence for acceptance. For transformer service, establish oil compatibility, processing-temperature behavior and the required insulation function separately.
Revisit the working point after the authorized history
A proposed assessment should pair a static height/load record with dynamic measurements under the defined preload, temperature, frequency and amplitude range. Where long-duration conditioning, thermal history or handling changes the support state, repeat the relevant observations at the resulting state.
Do not infer a new resonance merely by substituting the later static secant into a vibration formula. A dynamic model needs the applicable dynamic stiffness, supported mass and other contacts. Likewise, a stable measured frequency does not prove that height or alignment has remained within its limit.
Release the pad with its geometry, installation state, height history and validated dynamic stiffness. Keep preload, temperature, force/displacement definitions, phase and uncertainty with the result, and state the conditions covered by any extrapolation.
Calculate pad load before selecting its dynamic test point
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume the 500-sheet, 300 × 500 mm packet is supported equally on four pads. Its nominal steel weight is 1294.55 N, giving 323.64 N per pad. With an assumed local static stiffness of 1,000 N/mm, the displacement screen is 0.3236 mm. If only two pads actually engage, load and predicted displacement both double. Establish the loaded contact state before measuring small-signal stiffness around that state.
Manufacturing controls. Control pad footprint, loaded thickness, dwell, temperature, contact engagement and yoke restraint. Establish the working load and amplitude for the selected pad; the full laminated assembly also contributes contact compliance. [2]
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] M. Pirnat, G. Čepon and M. Boltežar, Introduction of the linear contact model in the dynamic model of laminated structure dynamics: an experimental and numerical identification, 2013, DOI 10.1016/j.mechmachtheory.2013.02.003.