Audit the geometry encoded in the production file. Repeating a rounded increment can shift the final position differently from rounding each full target, even when both exports look convincing in the drawing preview.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
Reconstruct exported values with their actual units, origin and coordinate semantics, then compare that numerical geometry with the design reference. Verify the machine’s physical feed separately using the controller specification and qualified inspection.
Follow the value through the data chain
Record the design unit, stored numerical precision, export unit and decimal policy, controller input interpretation and any later conversion. A displayed three-decimal dimension may be backed by more precise stored geometry—or may already have lost information. Determine which values drive the export.
Distinguish representable command increments from physical positioning capability. A controller accepting 0.001 mm numbers does not recover digits that an exporter removed at 0.01 mm, and that accepted numeric resolution does not prove 0.001 mm cutting accuracy.
Determine whether the released file expresses absolute target positions, relative increments or a pattern expanded inside the controller. Record the active physical unit, origin and offsets. Reconstruct the nominal target sequence using the actual file semantics.
For a proprietary cutting file, obtain the equivalent semantics from its actual specification. Units, origins and active offsets must be known before the numbers can be compared.
Compare full-target rounding with repeated-increment rounding
Let Q round to the nearest export quantum q. For an exact intended increment Δ and starting coordinate x0 = 0, the intended nth target is xn = nΔ.
If each full target is independently rounded, the represented position is Q(nΔ). With nearest rounding, its error is bounded by q/2 for each target, assuming no other numerical conversion or reference error.
If the same rounded increment Q(Δ) is repeated n times, the represented position is nQ(Δ). Its error is:
en = n[Q(Δ) − Δ]
This error is systematic. Repeating the same number does not make its rounding errors independent random samples. For this declared scheme, the magnitude bound n q/2 is a conservative bound, not a statistical standard deviation. Different increments require a sum of their individual errors.
An exact-decimal teaching example
Assume Δ = 0.3333 mm, q = 0.01 mm and nearest rounding with half-up tie handling. The origin is exact and no later conversion is applied. These are numerical assumptions, not a recommended step-lap displacement or export precision.
The exported repeated increment is 0.33 mm, so each repetition contributes −0.0033 mm of target error.
| Repetition n | Intended xn, mm | Rounded full target, mm | Full-target error, mm | Repeated rounded-increment position, mm | Increment-chain error, mm |
|---|---|---|---|---|---|
| 1 | 0.3333 | 0.33 | −0.0033 | 0.33 | −0.0033 |
| 3 | 0.9999 | 1.00 | +0.0001 | 0.99 | −0.0099 |
| 10 | 3.3330 | 3.33 | −0.0030 | 3.30 | −0.0330 |
| 20 | 6.6660 | 6.67 | +0.0040 | 6.60 | −0.0660 |
At n = 20, both outputs originated from the same intended geometry, yet their represented endpoints differ by 0.07 mm. The full-target error is still within ±0.005 mm; the repeated-increment error has accumulated to −0.0660 mm.
The discrepancy is in the encoded positions before the machine moves. Offset errors, feed errors and other equipment effects require separate machine verification.

Audit the exported file in a fresh reconstruction
Save the precise design reference and its revision. Parse the final exported file using the actual unit, origin, distance mode, parameter expansion and rounding rules. Reconstruct each intended lamination feature and step position from that file rather than from the drawing preview that generated it.
Compare corresponding feature coordinates and the functional relationships: step displacement, required overlap, relevant hole or notch locations and repeated-pattern endpoints. Maintain part, layer and step identity during matching. A small maximum coordinate error does not validate a file whose parts are assigned to the wrong layer.
Also compare local differences. For independently rounded full positions, the difference between adjacent represented positions can differ from its intended increment by as much as q when the two endpoint errors have opposite signs. A good final endpoint alone can therefore coexist with a poor local step relationship. The example isolates one coordinate; it is not a complete joint qualification.
If the controller applies another quantization, reconstruct that stage too. An export value that lies on one numeric grid may be changed by a second grid or unit conversion. Do not assume that displaying more decimal places changes the stored command or the controller’s actual interpretation.
Tie the numerical result to a design-approved decision
Use the released geometric tolerances and the allocated numerical error budget to decide whether the reconstruction is acceptable. The audit should identify the largest signed feature errors, affected step relationships, closure discrepancy and the assumptions behind their calculation. The ±0.005 mm bound in this example is a rounding bound, not an approved manufacturing tolerance.
If the numerical geometry is wrong, correct the generation or conversion rule under revision control and repeat the reconstruction. A hand-edited final increment can make one endpoint look right while leaving earlier relationships changed; it is not evidence that the pattern has been restored.
Verify the physical output with qualified dimensional inspection after the numerical reconstruction passes. The audit then traces each step from design geometry through encoded commands to produced parts, giving production a clear place to investigate any discrepancy.
Put export drift beside the lamination gauge
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] In the assumed 20-increment example, the repeated rounded increment misses its target by 0.0660 mm. Relative to the catalog steel gauge, this is 0.0660/0.23 = 28.70%. Independently rounding each full target limits its export error to 0.005 mm, or 2.17% of that gauge. These ratios describe geometric scale. Allocate the permitted numerical error from the joint drawing, then select an export route that stays inside it before machine-positioning errors are added.
Manufacturing controls. Control rounding mode, unit conversion, absolute versus incremental semantics and the final layer sequence. Gauge-scale comparison helps identify numerical errors that are large enough to deserve a joint-geometry review.
IEC 60404-8-7 covers supplied grain-oriented electrical-steel magnetic and geometric characteristics. Carry the approved supplied grade and dimensional basis into this manufacturing record. [2]
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.