Chenfan Electric
EN
Send drawing

ARTICLETechnical article

Layer-Length Compensation for Rectangular Wound-Core Corners

  • Chenfan Power

Calculate each layer’s developed length from its centre-line path, then add the joint allowance defined by the drawing. Keep the layer radius, pitch and joint geometry explicit so the cutting table follows the actual wound-core build.

Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.

For concentric rounded rectangles with constant spacing, the geometric length increment is 2πp per layer, where p is the distance between adjacent strip centre lines. That compact result is useful only after the drawing defines which lengths remain straight, which radii belong to which layer, and how the joint interrupts the closed path. Use the geometry as the baseline for the joint and process allowances.

Define the path before calculating the cut length

Cold-rolled grain-oriented electrical steel (CRGO) is a layered material in this application, not a solid rectangular ring. Label layers from the window outward: i = 1, 2, …, N. Use the following definitions, all in millimetres:

SymbolMeaningRequired distinction
a, bHorizontal and vertical tangent-to-tangent straight lengthsNeither is the outside width or height
r₀Corner radius of the innermost material surfaceNot the first layer centre-line radius
tPhysical strip thickness used in this modelKeep its measurement basis explicit
pEffective spacing between adjacent layer centre linesMay include coating and any represented separation
rᵢCentre-line radius of each corner in layer iIncreases outward in the concentric model
JᵢSigned geometric allowance for the specified jointDefined separately by the joint design
Three concentric rounded rectangle centre lines with shared tangent lengths and layer-specific radius calculation.
Layer-specific corner radii and length calculation

Assume four equal quarter-circle corners, parallel straight sections and equal pitch. Also assume the developed-length reference follows the geometric strip mid-thickness. These are explicit approximations. They do not prove that the mechanical neutral surface remains at mid-thickness during tight plastic bending.

rᵢ = r₀ + t/2 + (i − 1)p
Pᵢ = 2a + 2b + 2πrᵢ
Lᵢ,target = Pᵢ + Jᵢ

Here Pᵢ is the complete geometric centre-line perimeter. Lᵢ,target is a proposed cut-length target after the independently defined joint term. Neither expression includes a validated correction for springback, material stretch or the transition of a continuous spiral from one layer to the next.

The following length progression is an independent geometric derivation for concentric rounded rectangles. Use the actual corner construction and joint definition when assigning production cut lengths.

[Figure: Concentric centre lines retain the same tangent straight lengths while corner radii increase. Conceptual diagram — not a manufacturing drawing; not to scale. Spiral transitions and actual joints are excluded.]

Why the straight portions do not grow in this model

Offset a rounded rectangle outward by distance p. The four arc centres remain fixed. Their radii increase by p, while the tangent-to-tangent straight lengths remain a and b. The total additional arc length is four quarter-circles of radius increment p: 4 × (π/2)p = 2πp.

The outer width and height nevertheless increase. There is no contradiction: the larger dimensions are already represented by the enlarged corner arcs. If the centre-line envelope dimensions of a layer are Wᵢ = a + 2rᵢ and Hᵢ = b + 2rᵢ, the equivalent expression is:

Pᵢ = 2(Wᵢ + Hᵢ) + (2π − 8)rᵢ
Pᵢ₊₁ − Pᵢ = 2πp    [equal-pitch, concentric rounded rectangles]

Using 2(Wᵢ + Hᵢ) + 2πrᵢ would count the corner-related portions twice. Conversely, replacing every layer radius with an average radius would erase the length progression. Both errors can produce a plausible total steel requirement while assigning the wrong length to individual layers.

A compensation table that can be recalculated

Assumed calculation inputs and results. Let a = 100 mm, b = 60 mm, r₀ = 10 mm, t = 0.230 mm, and p = 0.250 mm. The pitch is an assumed geometric input; it is not a Chenfan coating specification. Set Jᵢ = 0 only to isolate the closed-path calculation. This does not prescribe a zero allowance for an actual joint.

Layer iCentre-line radius rᵢ, mmGeometric perimeter Pᵢ, mmIncrease from layer 1, mm
110.115383.5540.000
210.365385.1251.571
511.115389.8386.283
1012.365397.69214.137
2014.865413.40029.845

For example, layer 20 uses r₂₀ = 10 + 0.230/2 + 19 × 0.250 = 14.865 mm. Its perimeter is 320 + 2π × 14.865 = 413.3995496 mm. The constant increment is 2π × 0.250 = 1.5707963 mm. Calculate with the unrounded values, then round once to the approved output resolution. Three displayed decimals do not establish a manufacturing tolerance.

Check individual closure and total strip demand separately

A layer-specific residual is eᵢ = Lᵢ,actual − (Pᵢ + Jᵢ), evaluated under the agreed length and inspection conditions. A negative residual indicates insufficient developed length relative to that target; it does not uniquely identify its cause. Incorrect radius, an omitted joint allowance and an inaccurate physical length can all produce it.

The sum Σeᵢ is a total-length balance for a set of pieces. It is not the seam gap of one outer layer. This distinction matters when someone reports an impressive “cumulative closure error” without stating what was summed.

If the only error is a constant pitch overestimate δp, with the first-layer centre-line radius correct, the length excess assigned to layer i is 2π(i − 1)δp. For N independent closed-path layer targets:

Outer-layer error = 2π(N − 1)δp
Total geometric length error = πδpN(N − 1)

For the same illustrative 20-layer case, δp = +0.001 mm gives an outer-layer target excess of 0.119381 mm and a total excess of 1.193805 mm. These are different observables. The second must not be reported as a 1.194 mm gap at one seam. If pitch varies by layer, replace (i − 1)p with the sum of the measured or specified preceding centre-line spacings.

Recognize the geometries that need a different model

A rounded rectangle with unequal circular corners requires the relevant arc angles and radii: Pᵢ = Σsₖ,ᵢ + Σθₖ,ᵢrₖ,ᵢ, with angles in radians. A corner formed by two local bends is not automatically equivalent to one smooth quarter-circle. A continuously wound strip follows a spiral; the closed-perimeter table does not represent its crossover or start and tail geometry. A cut-and-reassembled core also requires its actual overlap, gap and grouping pattern.

Where tight bending moves the effective developed-length reference away from geometric mid-thickness, a validated bend allowance or observed developed length is needed. Do not correct this by silently changing p: pitch describes the layer spacing, whereas bend allowance describes the developed path through a bend. Keeping them separate makes the model auditable.

Release a table with its evidence

An OEM-ready compensation record should retain the drawing revision, layer order, radius definition, thickness and spacing basis, joint convention, unrounded calculated lengths and the output resolution. Check selected inner, middle and outer layers against the same geometric reference, then inspect the signed residual pattern.

A constant residual suggests a different investigation from a residual that grows with layer number. Those patterns are screening clues, not automatic diagnoses. Before changing a production table, confirm that the compared lengths use the same tension, temperature and measurement definition, and that the inspection condition matches the drawing state.

Deliver a traceable length target for every layer, with its intended path and signed closure residual. Release magnetic performance and finished-core tolerances against their own measured acceptance requirements.

Recalculate the layer increment with a sourced steel thickness

Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Keep the existing rounded-rectangle assumptions but set a separate ideal no-separation pitch p = t = 0.230 mm to isolate the nominal steel contribution. Then ΔP = 2πp = 1.44513 mm per layer. For 20 layers, the outer-layer increase over layer 1 is 27.4575 mm. Using the original assumed 0.250 mm effective pitch instead increases that result to 29.8451 mm, a 2.38761 mm difference. Select the pitch from the qualified assembled state before exporting individual lengths. [2]

Manufacturing controls. Control gauge, coating, seating, corner radii, tension, joint allowance and output rounding. Retain the centreline geometry and each layer target so a correct total demand cannot conceal incorrect individual closure.

References

[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.

[2] T. Takamiya, K. Hanazawa and T. Suzuki, Recent Development of Grain-Oriented Electrical Steel in JFE Steel, JFE Technical Report No. 21, 2016, Section 2.2.

Chenfan Electric

Direct coordination

Start a conversation.

A drawing, a material requirement, or a project to discuss.

Send drawing