35HP115 technical data sheet
thyssenkrupp Electrical Steel · 0.35 mm · Published core loss and magnetic properties
Grade comparison and supply
50 Hz · 0.35 mm
Find a Chinese alternative
Share your drawing or core loss target to check available grades.
Quote alternative60 Hz · 0.35 mm
Find a Chinese alternative
Share your drawing or core loss target to check available grades.
Quote alternativeGrade summary
thyssenkrupp Electrical Steel · 0.35 mm · 50 / 60 Hz
3 published records · Published flux density range 1.7 T
| Metric | Test point | Value | Source |
|---|---|---|---|
| Specific core loss | 50 Hz · 1.7 T | 1.15 W/kgGuaranteed maximum | PDF page 23 |
| Specific core loss | 60 Hz · 1.7 T | 1.51 W/kgGuaranteed maximum | PDF page 23 |
| Magnetic polarization | 800 A/m | 1.88 TGuaranteed minimum | PDF page 23 |
Download the PDF for the full published tables, test conditions and source references.