35ZH110 technical data sheet
Nippon Steel · 0.35 mm · Published core loss and magnetic properties
Grade comparison and supply
50 Hz · 0.35 mm
Find a Chinese alternative
Share your drawing or core loss target to check available grades.
Quote alternative60 Hz · 0.35 mm
Find a Chinese alternative
Share your drawing or core loss target to check available grades.
Quote alternativeGrade summary
Nippon Steel · 0.35 mm · 50 / 60 Hz
8 published records · Published flux density range 1.5–1.7 T
| Metric | Test point | Value | Source |
|---|---|---|---|
| Specific core loss | 50 Hz · 1.7 T (B) | 1.10 W/kgGuaranteed maximum | PDF page 5 |
| Specific core loss | 50 Hz · 1.5 T (B) | 0.81 W/kgTypical | PDF page 6 |
| Specific core loss | 50 Hz · 1.7 T (B) | 1.06 W/kgTypical | PDF page 6 |
| Specific core loss | 60 Hz · 1.5 T (B) | 1.08 W/kgTypical | PDF page 6 |
| Specific core loss | 60 Hz · 1.7 T (B) | 1.41 W/kgTypical | PDF page 6 |
| Magnetic induction | 800 A/m | 1.88 TGuaranteed minimum | PDF page 5 |
| Magnetic induction | 800 A/m | 1.92 TTypical | PDF page 6 |
| Magnetic induction | 2500 A/m | 1.96 TTypical | PDF page 6 |
Download the PDF for the full published tables, test conditions and source references.

