Measure core-packet relative motion against a justified assembly reference. Select the optical arrangement for the expected surface movement, verify the residual quantity’s uncertainty and preserve the coating and contact state during pattern preparation.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
Start by naming the packet surfaces and the reference structure. Then decide how to observe them without changing the coating, contact or insulation system whose behaviour is being assessed.
Make the pattern compatible with the component
The iDICs Good Practices Guide for Digital Image Correlation, Edition 2, recommends evaluating a surface’s natural pattern before applying a new one. It also warns that a surface coating may not move or deform with the underlying material. A well-correlated image of a loose coating can be a poor measurement of the steel beneath it. [2]
Where an applied pattern is necessary, qualify its application and removal for the actual coating and intended assembly. The guide requires a non-invasive pattern and warns about stiff or thick applied layers and destructive preparation. Its general metal-cleaning examples are not permission to abrade or solvent-clean coated core laminations.
For a core-packet study, keep the approved pattern away from functional contact faces and interlayer interfaces unless that modification is explicitly part of the assessment. Do not let a label or continuous film bridge two independently moving packet surfaces. Such a marker could track itself, constrain the motion or obscure the boundary being measured.
The marker must follow its intended surface and retain contrast throughout the measurement. Record the region observed, preparation, pattern identity, illumination and any evidence of detachment or change. A process demonstrated on bare metal is not automatically compatible with a particular lamination insulation system.
Select 2D or stereo from the expected motion
A single-camera 2D-DIC analysis assumes a planar surface with an appropriate camera alignment and constant stand-off distance. The 2025 guide explicitly warns that out-of-plane translation and rotation cause errors in that representation and strongly recommends stereo-DIC where feasible.
Core packets can present stepped surfaces, rotation and changing camera distance. Assess those features before interpreting an apparent in-plane shift. Stereo-DIC can recover three-dimensional surface motion with a suitable calibration; it still needs stable optics, sufficient visibility and verified uncertainty for the displacement component of interest.
Removing a fitted in-plane rigid motion does not automatically correct out-of-plane projection errors in 2D-DIC. The reference and candidate surfaces can experience different optical errors, particularly when their planes or depths differ. Preserve the actual geometry and expected motion in the measurement design.
Define the rigid reference before examining the candidate motion
A relative-motion quantity needs an explicit reference. Select a region expected to move rigidly with the chosen assembly reference, and justify that choice independently of the packet whose movement is under investigation. A moving fixture or deforming reference region can change the interpretation.
For finite planar rigid motion, the predicted point displacement is u_rigid(r) = t + (R − I)r, where t is translation, R is the rotation matrix, and r is the reference point coordinate. The residual is u_measured − u_rigid.
Use an appropriate fit across sufficient reference points and retain its uncertainty. Fitting the candidate’s entire motion as the reference can absorb some of the very relative motion being sought. The rigid fit removes the declared common motion, not every legitimate deformation.
An original residual example with an explicit approximation
Assume a preselected reference independently supplies t = (0.200, 0.100) mm and a small counterclockwise rotation θ = 0.001 rad. For this illustrative calculation, use the first-order planar approximation:
u_rigid(x,y) = (0.200 − θy, 0.100 + θx) mm.
Take points A = (0,0) mm and B = (50,0) mm. Their predicted rigid displacements are A: (0.200,0.100) mm and B: (0.200,0.150) mm. Now invent measured outputs A: (0.200,0.100) mm and B: (0.203,0.150) mm.
After subtraction, A has zero residual and B has (0.003,0) mm, or 3 µm in x. All coordinates and outputs are hypothetical; no factory displacement was measured. With an assumed image scale of 0.020 mm/px, the 3 µm result corresponds to 0.15 px.
The exact rotation would change B’s predicted x displacement by approximately −0.000025 mm relative to this first-order example. Use the exact transformation when that approximation error matters. Here the calculation deliberately exposes both its geometric model and its scale conversion.

Verify the residual quantity’s measurement floor
The iDICs guide distinguishes variance and bias errors. It calls for noise evaluation under representative acquisition and processing conditions, with static and rigid-motion image studies serving different purposes. A static-image check alone can provide only a lower bound on errors encountered during movement. [2]
Evaluate the same residual quantity used to judge the packets. Include correlation processing, camera stability, calibration, rigid-reference fitting, image scale and relevant projection effects. Do not equate a software’s subpixel output precision with a demonstrated displacement detection limit.
Suppose the same residual-processing chain gives an assumed temporal standard deviation of 2 µm in a suitable no-relative-motion study. The 3 µm output is then 1.5 times that stated deviation. This ratio alone does not establish significant slip: it lacks the adopted decision criterion, bias assessment and uncertainty of the reference transformation. The guide makes the acceptable noise-floor criterion application-specific; this article imposes no universal one- or three-standard-deviation rule.
Deliver raw images, calibration, processing settings, validity masks and the justified reference transformation with the residual field. Report the visible surfaces, observation period and uncertainty, then use the measured relative motion to guide the mechanical investigation.
Resolve a sheet edge before claiming interlayer motion
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] At the assumed image scale of 0.020 mm/pixel, one nominal steel gauge spans 0.23/0.020 = 11.5 pixels. The 3 µm residual in the existing example is only 0.15 pixel. That separation of scales can support assigning a visible edge to a layer, but it does not validate subpixel displacement by itself. Demonstrate the residual-processing floor with the same surface, lighting, reference subtraction and expected out-of-plane motion before interpreting slip. [2]
Manufacturing controls. Control surface pattern adhesion, layer identity, camera geometry, measurement scale and reference-region stability. Match preload and restraint during the no-relative-motion check and the subsequent packet trial.
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] E. M. C. Jones and M. A. Iadicola (eds.), A Good Practices Guide for Digital Image Correlation, Edition 2, 2025, DOI 10.32720/idics/gpg.ed2.