Evaluate Jiles–Atherton fits by the predictions they support. Near-equivalent loop residuals can leave several parameter sets consistent with the experiment while those sets disagree on a new excitation history.
Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.
The useful decision is whether the parameters are sufficiently constrained for the intended prediction. Examine local parameter sensitivity, repeat the search from different initial values and challenge the retained solutions with excitation histories that were not used for fitting.
Lock the model variant and state first
State saturation magnetization, anhysteretic field scale, reversibility, pinning and coupling parameters for the exact model variant being identified. Retain directional axes and internal-state definitions with any vector extension.
Specify the exact equations, units, directional convention and numerical treatment used by the identification code. Keep the initial magnetic state and ordered excitation attached to every simulated trajectory. Comparing parameter tables from different model variants without those definitions can create an apparent disagreement that is actually a change of model.
Also declare what is fitted: magnetization, flux density, a winding current or a circuit output. A circuit observable may constrain combined material and circuit behavior. It should not be treated as an independent measurement of every material parameter.
Separate optimizer behavior from identifiability
Repeat the numerical search from different admissible starting points and retain near-equivalent fits. Optimizer convergence identifies a solution of the chosen fitting problem; independent observations determine whether the parameters are distinguishable.
There are two different questions. Did the numerical search miss a better solution? Does the available dataset distinguish the parameters even if the search is excellent? Multiple starts help investigate the first and can expose the second, but a single successful start answers neither completely.
Use physically and mathematically admissible bounds with their basis recorded. Preserve all near-equivalent solutions under a declared comparison criterion. Do not silently reject a solution because it disagrees with the preferred parameter table when its residual and constraints are comparable.
Scale parameters before comparing sensitivities
Scale sensitivity coordinates to avoid confusing parameter magnitude with information content. Improved numerical conditioning cannot supply an independent observation missing from the experiment.
A practical proposed analysis uses scaled coordinates q_j = θ_j/s_j, with nonzero reference scales s_j and a stated transformation for bounded parameters. Let r_i be the residual divided by a declared observation scale w_i. Form the sensitivity matrix J_ij = ∂r_i/∂q_j along the complete ordered trajectory.
When using numerical perturbations, check sensitivity to step size and integration settings. A perturbation that changes branch treatment or initialization can measure a numerical inconsistency instead of parameter sensitivity. Near a boundary, use an appropriate admissible perturbation and document its limitations.
Compare normalized column directions and singular values of J. Nearly parallel columns indicate that a change in one parameter can be compensated by another for these observations. A column-direction cosine is a sensitivity diagnostic; it is not automatically a statistical correlation coefficient for estimated parameters.
A nearly singular information matrix requires care. Do not invert JᵀJ and report precise confidence intervals without checking rank, the observation-error model and the validity of the local approximation. Bounds or penalties may stabilize a solution while the data remain weakly informative.
An exact toy example of indistinguishable fits
Consider a deliberately simple two-coordinate surrogate, unrelated to any particular Jiles–Atherton parameter values. Its fitted observations are y₁ = q₁ + q₂ and y₂ = 2q₁ + 2q₂, with target values 3 and 6. Coordinates and outputs are dimensionless.
Candidate A has (q₁, q₂) = (1, 2); candidate B has (2, 1). Both exactly match both targets. The sensitivity matrix has rows [1, 1] and [2, 2]. Its columns are identical, its rank is one and its singular values are √10 and zero. The fit identifies the sum, not the two coordinates separately.
Now reserve a different observable z = q₁ − q₂. Candidate A predicts −1 and candidate B predicts +1. Adding its sensitivity row [1, −1] gives a rank-two matrix with singular values √10 and √2. This shows how an independent direction can distinguish solutions that a repeated version of the original observation cannot.

The algebra is an identifiability illustration, not a pair of fitted steel loops, a simulation of the Jiles–Atherton equations or evidence that a particular laboratory protocol will achieve these ranks. Its role is to make the difference between repeating information and adding information explicit.
Compare retained fits on held-back histories
For the actual magnetic model, retain parameter sets from multiple starts with the same equations, bounds, initial-state definition and objective. Compare their predictions on relevant minor loops, biased trajectories or other histories excluded from identification. Choose the challenge to probe the sensitivities that the fitting data leave weakly constrained.
Inspect the whole ordered response and the observable needed by the application. A common outer-loop residual can conceal disagreement in reversal slope, remanence or cycle energy.
Avoid changing rate, stress, direction and temperature simultaneously without a model capable of separating those effects. Otherwise a failed prediction may reveal model inadequacy rather than only parameter ambiguity. Keep numerical convergence and measurement comparison capability in the review.
Report ambiguity in terms of the engineering decision
If retained fits disagree materially on the target prediction, supply that spread with its conditions and identify the additional evidence needed. It is a conditional prediction range from a selected solution set, not a probability distribution unless a justified statistical model has been supplied.
Use the model for the target prediction when the retained fits agree within the required comparison capability, and report any remaining parameter ambiguity. Keep that supported purpose explicit so phenomenological coefficients are interpreted at the resolution the data provide.
Use the catalog point as a check on prediction, not identity
The M-3X catalog maximum at 1.7 T and 50 Hz is 0.998694 W/kg. [1] Assume two candidate accounting splits: A assigns 0.400000 W/kg to a rate-independent contribution and 0.598694 W/kg to the remaining contribution; B assigns 0.600000 and 0.398694 W/kg. Both reproduce exactly the same total. Their first contribution differs by 50%, so equality of one total cannot establish separate physical parameters. Preserve both fits until loop shape, rate response or another independent measurement distinguishes them. These allocations illustrate the identification problem and carry no measured mechanism assignment.
Control specimen direction, processed gauge, cutting stress, annealing and the assembly joint state when selecting calibration and validation histories. A changed manufacturing state can explain a failed prediction even when an optimizer reproduces the original fitting loop. IEC 60404-8-7 provides the delivery-specification framework for fully processed grain-oriented steel. [2]
References
[1] Cleveland-Cliffs, Grain-Oriented Electrical Steels — LITE CARLITE and Mill-Anneal, October 2023, Tables 1 and 5; Stress-Relief Annealing.
[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.