Chenfan Electric
EN
Send drawing

ARTICLETechnical article

Multi-Width Slitting Plans: Useful Remnants and Nominal Yield

  • Chenfan Power

Plan slitting across the coil set and the orders it must supply. The first coil’s width score matters only alongside the remaining stock, confirmed demand and remnants that can actually enter a compatible job.

Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.

Treat each remnant as a controlled stock item with a usable width, available length, material identity, condition and compatible demand. Use those inputs to assign retained-stock value and compare complete plans on the same demand horizon.

Qualify the remnant before giving it credit

Retained stock has future value only when its dimensions, material identity and retrieval route satisfy a defined later use. Optimize against the declared demand horizon, and keep retained inventory separate from completed order output.

For multi-width slitting, qualify each remnant against an identified compatible use. A proposed remnant qualification should include the approved material route, thickness and coating identity; measured usable width and tolerance; length or mass available; condition and protection; traceable storage location; and the processing route by which it can meet a compatible order.

Use the remaining usable width after required edge exclusions and recutting allowances. A nominal 300 mm remainder is not necessarily able to produce a 300 mm accepted strip. Required trimming and width tolerance may consume the entire margin. Any minimum reusable width should come from the qualified machine and order requirements, rather than from an arbitrary percentage of parent width.

A remnant above that minimum can still be incompatible with the next job. Grade approval, available length, coating condition or the permitted batch allocation may prevent use. Keep physical reusability separate from confirmed demand compatibility.

Plan the coil set, not only the next pattern

For each feasible slitting pattern, record the quantity of each required width, the parent stock consumed, the generated remnant type and any process restrictions. Pattern counts are integers; demand and stock limits connect them across the coil set. Do not give the optimizer unrestricted permission to produce excess strips just to improve a width score.

The objective needs an explicit treatment of present accepted output, retained stock and waste. This planning model can assign different weights to creating new remnants and consuming older stock. Set those weights from the actual storage, handling and later-use requirements. For CRGO, use the actual inventory and order basis to determine whether retaining another width is worthwhile.

Record setup, minimum run length and other qualified process constraints where they affect feasible patterns. A width combination that sums correctly can still be unavailable on the actual line. The numerical example below deliberately omits those details so its cross-coil demand effect can be checked independently.

Two-coil width-scaled slitting plans and balances comparing greedy 940/420 allocation with mixed 680/680 allocation
Original width-scaled plans and reconciled width balance. Both meet the same current demand. Plan G still lacks one future 300 mm strip; its retained 280 mm is not credited as that order’s accepted output.

Two coils with the same current demand

Assume two parent coils, each with 1,000 mm of usable width after all required parent trim, and the same usable length. Current demand is two strips of width A = 420 mm and two of width B = 260 mm, each using that full length. Both parent coils and all resulting strips are assumed to have compatible material identity and length.

For this teaching example, assume zero additional trim or width loss, that suitable recutting is available, and that a remainder below 250 mm is not retained. The next confirmed compatible demand is two 300 mm strips of the same length. These assumptions are not CRGO machine limits, approval criteria or actual orders.

PlanFirst coilSecond coilCurrent output width totalResidual widths
G: highest current first-coil fill420 + 260 + 260 = 940 mm420 mm1,360 mm60 and 580 mm
M: mixed across both coils420 + 260 = 680 mm420 + 260 = 680 mm1,360 mm320 and 320 mm

Given the declared current quantities, 940 mm is the largest feasible current-demand fill on the first coil. Its 94% first-coil score looks attractive beside 68% for Plan M. Across both coils, however, each plan supplies exactly the same current demand: 1,360 / 2,000 = 68% of usable input width.

Plan G cannot cut two 300 mm strips from its residuals. The 60 mm remainder is below the assumed retention threshold; 580 mm accommodates only one 300 mm strip and leaves 280 mm. That 280 mm qualifies for retention under the assumed width threshold but cannot meet the second 300 mm demand. It remains inventory, not completed order output.

Plan M can cut one 300 mm strip from each 320 mm remainder, leaving 20 mm from each. It meets both future strips, with 40 mm total width assigned to waste under the declared assumptions.

Width balance after the available future cutsPlan G, mmPlan M, mm
Accepted current output1,3601,360
Accepted next-order output300600
Retained stock2800
Waste6040
Total usable input2,0002,000

Equal usable lengths make these width fractions equivalent to area fractions. Plan G credits 83% of input to these identified orders and retains 14%; Plan M credits 98% to the identified orders. This is not a comparison at equal completed future demand: Plan G still owes one 300 mm strip. Its additional sourcing or production requirement is outside the example.

Release the plan against its demand horizon

The counterexample shows that a locally best fill can be inferior for a declared demand horizon. It does not prove that mixed patterns always win, or that retained stock has no value. Change the next order to a compatible 280 mm requirement, add recutting allowances or restrict the available lengths, and the comparison changes.

Release the plan with its complete width balance, qualified remnant records and stated future-demand basis. Show present output, confirmed future allocation, unallocated retained stock and waste separately. Label forecast orders as forecasts, so possible reuse stays distinct from realized accepted output.

Compare order output on a steel-mass basis

Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume each parent in the width example has 100 m of usable length. The two 1,000 mm parent widths then represent 351.90 kg of nominal steel. Plan G allocates 292.077 kg to the identified current and future orders, while Plan M allocates 344.862 kg. The difference is 52.785 kg, exactly one 300 mm × 100 m strip. Plan G still owes that strip; retain its 280 mm stock with its own identity rather than reporting the order as complete.

Manufacturing controls. Control usable width after trimming, gauge, retained length, grade compatibility, recutting allowance and actual demand. Use the width optimizer only after those manufacturing constraints are loaded.

IEC 60404-8-7 covers supplied grain-oriented electrical-steel magnetic and geometric characteristics. Carry the approved supplied grade and dimensional basis into this manufacturing record. [2]

References

[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.

[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.