Chenfan Electric
EN
Send drawing

ARTICLETechnical article

Hot Support Creep in Wound-Core Annealing Fixtures

  • Chenfan Power

Qualify an annealing fixture against loaded deformation through its temperature and exposure history. Measure support-profile change, then track how the altered contacts affect core position and shape. This gives the fixture a dimensional acceptance basis alongside its material compatibility.

Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.

Start with the fixture’s actual temperature, load path and exposure history. Then measure its residual geometry in a repeatable cold state and investigate how that change reaches the core. A bent support and a distorted core are related hypotheses, not interchangeable measurements.

Qualify the support against hot load and duration

Creep is time-dependent permanent deformation under stress. A room-temperature strength value cannot establish resistance to it, and a maximum service temperature in air does not specify an acceptable loaded deflection. Creep deformation data and creep-rupture data also answer different questions: the fixture may exceed a dimensional allowance well before a rupture criterion becomes relevant.

For the selected fixture alloy and fabricated condition, obtain hot-load deformation and duration data alongside oxidation and service-temperature information. Assess supports and welds at their actual metal temperatures, spans and remaining sections.

Request evidence for the supplied grade, product form and condition, including any welds in a load-bearing section. Match the data to a deformation criterion at the relevant stress, temperature and duration. Long-duration constant-temperature rupture tables cannot simply be divided by the number of hours in a furnace hold to predict cycle-by-cycle sag.

For the assessment, record:

Required inputWhy it matters
Fixture metal temperature through the cycleFurnace setpoint alone does not establish the support’s thermal exposure
Core and fixture weight, support span, restraint and contact positionsThese define bending, contact and weld loads
Loaded dwell, heating and cooling history, and prior cyclesRepeated exposure and temperature changes affect the component’s history
Grade, product form, supplied condition, weld condition and remaining sectionPublished bulk-material properties do not describe every fabricated or aged support
Maximum permitted support-profile changeSurvival without fracture is not a dimensional acceptance criterion

Atmosphere and surface attack belong in material compatibility, but this assessment does not prescribe a furnace gas composition or an annealing schedule. The approved route for the actual core material remains a separate input.

Measure residual sag without calling every deviation creep

Establish a fixture profile before exposure, using defined datum pads and the same orientation in every measurement. After cooling and unloading, repeat the survey at the same reference temperature. Include support midspans, welds, joints and the actual contact pads. A fitted straight line or datum plane must be defined consistently; otherwise a changed alignment can look like changed sag.

At survey coordinate s, define Δz_res(s) = z_after(s) − z_before(s), with positive z downward and both profiles referred to the same cold datum. Report the profile rather than only its largest value. A single maximum does not show whether a support has bowed, twisted or changed the relative height of its contact pads.

This measurement establishes residual geometry change. It does not uniquely establish creep as the cause. Permanent distortion can also involve thermal gradients, local yielding, weld movement, joint settlement, section loss or damage from handling. Assess hot-load deformation, thermal cycling, fabrication and weld condition separately. A rupture criterion does not establish the permitted support-profile change.

A matched unloaded or lightly loaded fixture exposure can help distinguish load-dependent deformation from effects that also occur without the core load. Keep the temperature exposure and measurement method comparable. Where attribution matters, combine the geometry records with the load history and examination of the affected section. One before-and-after survey is not a complete creep characterization.

Conditional chain linking annealing fixture temperature and load to residual support sag, contact changes and separate core tilt or shape distortion
Conditional error chain from fixture thermal exposure to support-profile change, contact redistribution and core geometry. Cold residual surveys and separate core measurements validate different links. Conceptual diagram — not a manufacturing drawing.

Distinguish hot movement from the shape left afterward

Cold inspection can miss deformation that was present only while the fixture was hot and loaded. A support may deflect elastically, expand or bow under a temperature gradient, then recover much of that movement after unloading and cooling. Conversely, a retained profile change may alter the starting geometry for the next cycle.

If hot displacement is required for a development study, use a qualified measurement arrangement and report its own reference movement and uncertainty. Measure the relevant fixture temperature at the same time. Do not subtract a room-temperature elastic calculation from an observed hot displacement and call the remainder creep unless the temperature-dependent stiffness, boundary conditions and thermal distortion have been validated.

The cold residual profile is therefore a useful screening record; it is not automatically the maximum hot sag or the deformation experienced by the core.

Validate each step between fixture sag and core distortion

The mechanical link is contact. If a support drops, a core may follow it, bridge over it, rotate as a whole, lose contact at one location or redistribute its reactions. The outcome depends on core stiffness, layer freedom, pad positions and other restraints. The transfer from fixture displacement to core distortion is not necessarily one-to-one.

An annealing fixture changes the mechanical boundary during the cycle. Record inner and outer contacts, retaining bands and the geometry held by each component. Determine the support-to-core deformation transfer on the actual construction.

Use paired observations: fixture contact-pad heights, evidence of contact or separation, and core position and shape referred to a defined core datum. Separate rigid-body movement from changes in the core’s own profile. Compare the core in a repeatable inspection support condition, so that removing the furnace fixture does not introduce an uncontrolled second comparison.

A small geometric example: tilt is not shape distortion

Assumed calculation inputs and results. Suppose two support pads are 400 mm apart and their relative height changes by 0.60 mm. If an ideal rigid body continues to contact both pads, its rotation is θ = arctan(0.60/400) = 0.001500 rad, approximately 0.08594°.

The ratio uses identical length units, so it is dimensionless before conversion to angle. This example predicts rigid-body tilt under the stated two-contact assumption. It predicts no bending of that ideal rigid body. A real laminated core could respond differently if contacts separate or restraints intervene. Consequently, neither 0.60 mm of support-height change nor the calculated angle is a measured core-distortion value.

Make fixture disposition follow evidence

Set fixture inspection intervals and allowable profile changes from a qualified material and mechanical assessment, supported by actual cycle records. Re-survey after an approved repair or straightening operation; a restored cold outline alone does not prove restored high-temperature performance.

Record fixture identity, material condition, exposure history and profile change together with the observed core-contact response. Verify the core’s magnetic result separately under matched test conditions when that mechanical state changes.

Express support sag on the layer-build scale

Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume the support carries a 500-layer build in the measured direction. Its nominal steel thickness is 115.00 mm. The assumed 0.60 mm support-height change equals 0.522% of that build and 2.61 nominal sheet gauges. Those scale comparisons make the fixture change worth investigating, but the two-pad model above predicts rigid-body tilt only. Measure the core contour after returning it to the specified final support before assigning any support-to-core distortion factor. [2]

Manufacturing controls. Control support span, hot contact area, fixture alloy condition, loaded temperature history, dwell, prior cycles and final datum shape. Select an anneal-compatible grade and qualify fixture movement within the actual core process.

References

[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.

[2] T. Takamiya, K. Hanazawa and T. Suzuki, Recent Development of Grain-Oriented Electrical Steel in JFE Steel, JFE Technical Report No. 21, 2016, Section 2.2.