Control cooling restraint as part of the delivered core condition. Compare the contraction required by the core with the movement allowed by its fixture, and verify that the arrangement preserves shape while releasing the intended thermal movement.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
This is a cooling-stage interface problem. A correct furnace setpoint or satisfactory soak does not establish the stress state after the temperature falls. Conversely, cooling in a fixture does not automatically create permanent damage: the contact geometry, restraint and subsequent release determine what remains.
Compare desired movement with permitted movement
For a uniform member over a limited temperature interval, its free thermal strain is approximately:
epsilon_T = alpha × DeltaT
Alpha is the applicable coefficient of thermal expansion in K⁻¹; DeltaT is the signed temperature change in K. Cooling gives a negative DeltaT. If alpha varies significantly with temperature, use its integral rather than a constant coefficient.
The mechanical strain is the difference between actual movement and free thermal movement. Paul Lagace’s Effects of the Environment explains this distinction and shows why an unconstrained uniform bar can expand without thermal stress. A wound core needs a more detailed contact model, but the same compatibility question applies.
For a simplified one-dimensional core/fixture pair, initially stress-free at the same length L, let delta_c,free and delta_f,free be their free length changes. If a much stiffer fixture forces the core to follow its movement without slip:
epsilon_mechanical ≈ (delta_f,free − delta_c,free)/L
sigma_trial ≈ E × epsilon_mechanical
E is the core material’s directional elastic modulus. These relations assume uniform temperature within each member, bilateral restraint, small deformation and linear elasticity. Actual contacts may transmit load only in one direction, open as dimensions change or slip through friction. A mandrel, outer cage and support saddle therefore cannot be assigned the same restraint condition simply because all are called fixtures.
Temperature difference matters even with similar materials
Identical expansion coefficients do not eliminate mismatch if the core and fixture cool at different rates. Nor does equal temperature guarantee equal movement when their expansion coefficients or effective dimensions differ.
Assumed calculation inputs and results. Consider L = 500 mm, assumed alpha_c = alpha_f = 12 × 10⁻⁶ K⁻¹, DeltaT_c = −100 K and DeltaT_f = −80 K. The core’s free contraction is −0.600 mm, while the fixture’s free contraction is −0.480 mm. If the idealized fixture holds the core to its own length, the core is stretched 0.120 mm relative to its free cooled condition. Mechanical strain is 0.120/500 = 0.000240.
Using E = 122,000 MPa gives an elastic trial stress of 29.3 MPa in tension. That modulus is a representative rolling-direction value from Cleveland-Cliffs’ 2023 GO steel brochure. [3] The expansion coefficients, temperatures and restraint are assumptions, not a supplier specification or measured furnace record. [3]
The 20 K difference creates a defined restraint demand in this bar model. For the layered hot core, use temperature-dependent modulus, yield and creep, the actual temperature distribution and fixture compliance to determine the release state.

Record two thermal histories and the contact state
Measure the temperatures relevant to the restrained interface, not only the furnace atmosphere. A core surface reading and a distant fixture reading may not describe the two parts whose relative movement is blocked. Sensor placement, response and attachment should be documented so the temperature comparison has a defined physical meaning.
At the same time, record the contacts capable of carrying force: locating points, mandrel contact, outer restraints, support surfaces and any friction-dependent interfaces. Identify which direction each contact restrains. A fixture that prevents inward contraction behaves differently from one that supports weight while permitting tangential movement.
Cleveland-Cliffs’ stress-relief guidance warns that excessive thermal gradients can reintroduce stress or distort shape and treats cooling as part of the controlled process. Its product-specific rates do not establish a general fixture-release schedule. The present question requires the additional contact and movement evidence. [3]
A useful record combines temperature histories with relative displacement or a defined dimensional check. Temperature mismatch alone shows a possible driving mechanism; it does not prove that force was transferred. Movement blocked at the relevant contact, or a change on controlled release, provides different evidence.
Validate staged restraint changes as a controlled comparison
Validate the release sequence within the approved thermal, atmosphere, handling and shape-support requirements.
Compare a reproducible reference cooling configuration with a candidate configuration that changes one identified restraint at a defined stage. Keep material, core geometry, furnace loading and thermal treatment comparable. Retain the time and temperature state of each change instead of labeling the sequence simply “early release.”
| Stage evidence | Question answered |
|---|---|
| Core and fixture temperatures at the restrained interface | What mismatch could drive relative movement? |
| Contact identity and permitted directions | Which movement can become load? |
| Dimensions immediately before and after the approved change | Does the restraint affect the observed shape? |
| Final dimensions and support state | Is the accepted geometry retained? |
| Matched magnetic measurements in the final state | Is the resulting magnetic condition acceptable? |
A difference that disappears after release is consistent with reversible elastic restraint. A persistent dimensional or magnetic difference requires further investigation; plastic deformation, changed joints, frictional seating and renewed final restraint are possible explanations. The observation does not identify one microscopic cause by itself.
Do not compare a freely supported reference with a clamped candidate and attribute every magnetic difference to the earlier cooling step. Final test restraint and excitation must be reproducible, and measurement uncertainty must be retained.
Release the measured final mechanical state
Document the fixture revision, relevant thermal histories, contact conditions, approved restraint-change stage, final geometry and magnetic acceptance state. “Annealed” describes a process history; it does not fully describe the delivered mechanical condition.
Qualify the cooling arrangement for required movement, retained shape and reproducible final magnetic performance. Combine the free-contraction screen with measured contacts, relative movement and final-state tests to close the actual core–fixture decision.
Compare cooling mismatch with the steel-build geometry
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume 500 layers lie through a 115.00 mm nominal steel build. Retain the assumed expansion coefficient 12 × 10⁻⁶ K⁻¹ and a 20 K temperature difference. The simple free-contraction mismatch across that build is 115.00 × 12 × 10⁻⁶ × 20 = 0.0276 mm. It is much smaller than the 0.120 mm mismatch over the separate 500 mm bar, because the reference lengths differ. Use the actual restrained direction and length before defining the cooling-contact review. [2]
Manufacturing controls. Control fixture/core temperature histories, permitted slip directions, contact pressure, layer seating and the release sequence. Calculate thermal mismatch with temperature-appropriate properties and verify the final dimensional and magnetic states.
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] J. A. Chambers, Preloaded Joint Analysis Methodology for Space Flight Systems, NASA TM-106943, 1995.
[3] Cleveland-Cliffs, Grain-Oriented Electrical Steels — LITE CARLITE and Mill-Anneal, October 2023, Tables 1 and 5; Stress-Relief Annealing