A capacitive test object can raise a test transformer’s output voltage through its interaction with source inductive impedance. Characterise loaded regulation and measure object voltage to establish the stress actually applied.
HIGHVOLT’s conventional-system brochure includes regulation, compensation and independent HV measurement as separate system functions. Their interaction must be represented when calculating loaded output. [1]

Write the source and load on the same side
Use a simple HV-referred Thevenin model: open-circuit source voltage E, series impedance Zs = R + jωL and object capacitance C. At object voltage V, its current is I = jωCV. With E = V + ZsI, the relationship becomes E = V[1 − ω²LC + jωRC].
Thus |V/E| = 1/√[(1 − ω²LC)² + (ωRC)²] under these linear sinusoidal assumptions. Keep the frequency, resistance, inductance and total capacitance together; a capacitance without the source parameters cannot determine regulation.
Total C includes the object and relevant HV accessories at the represented terminal. Do not insert an LV leakage inductance into an otherwise HV-referred model without conversion.
Calculate a regulation curve within a supported region
For an illustrative E = 100 kV, f = 50 Hz, L = 20 H and C = 10 nF, neglecting R gives ω²LC ≈ 0.01974 and V ≈ 102.01 kV.
| Curve entry | Quantity to calculate or measure |
|---|---|
| Object family point | Total capacitance and intended voltage |
| Source condition | Frequency, regulator position and equivalent impedance |
| Loaded result | Actual object voltage and capacitive current |
| Model difference | Measured voltage minus predicted voltage, with uncertainty |
| Boundary flag | Control limit, excessive current or proximity to an unsupported resonance region |
As the ideal denominator approaches zero, the simplified model predicts increasing amplification. Real losses, nonlinear magnetic behavior, source limitations and controls become decisive. The equation should identify that boundary, not be used to claim an attainable unlimited voltage.
Compare with the actual controlled system
Include compensation equipment where present. It can change input current and the effective circuit without eliminating the need to measure the object’s voltage. A regulator maintaining an LV quantity does not necessarily maintain the HV terminal quantity through a changing load.
Verify representative capacitance points with the designated calibrated HV measurement system and the approved test arrangement. Capture voltage shape as well as RMS level where required by the test basis.
Use the regulation record to identify controllable load points within the supported source boundary. Resolve prediction-to-measurement differences through impedance, accessories and control response before setting the test voltage.
Compare two capacitive regulation points
Apply the same-reference leading capacitive current to the inductive source impedance [2]. The following pair holds internal E fixed first, then solves the E needed to hold object voltage fixed; these are different control comparisons.
For the assumed 50 Hz, 20 H HV-referred inductance, 100 kV open-circuit source and negligible resistance, 10 nF gives 102.014 kV output while 20 nF gives 104.110 kV. To hold the latter load at 100 kV in this linear model, internal source magnitude must be 96.052 kV. Verify measured regulation and controller limits instead of retaining the unloaded ratio setting.
References
- HIGHVOLT Prüftechnik Dresden GmbH, HVAC Test Systems Based on Transformers, 1.10/5 WP, November 2020.
- U.S. Department of Energy, DOE-HDBK-1011/3-92, Electrical Science, Volume 3, June 1992.