Identify the reference conductor before testing capacitance-matrix row sums. A complete closed conductor system and a grounded reduced matrix preserve different potential-shift tests; both can be symmetric and physically consistent.
Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.
For a complete, closed electrostatic conductor system, shifting every conductor by the same potential produces no field or charge change. A reduced matrix with the tank fixed at zero instead sees a real voltage change when all retained winding nodes rise together. Confusing those tests can erase legitimate winding-to-tank capacitance.
Define the nodes and the electrostatic boundary
Start with the conductor list, reference, geometry and charge definition. A node may represent an equipotential winding section, terminal, screen or tank surface under the chosen approximation. An entire winding with a distributed high-frequency voltage is not automatically one equipotential conductor.
The discussion here concerns a linear, reciprocal, quasistatic electrostatic model with real capacitances. It excludes dielectric dispersion, conductive leakage and inductive voltage contributions. Those effects need their own frequency-dependent model; a complex terminal admittance is not simply the static matrix below.
The full-system example includes two winding-section nodes and an enclosing reference conductor, with no unrepresented exterior field. An open-domain calculation referenced to fixed infinity must retain that reference in its interpretation. A uniform shift of only the finite conductors relative to infinity is not the full common-potential invariance test.
Extract charge coefficients rather than mixing notations
Write the Maxwell charge relation as q = C v, with q in coulombs, v in volts and C in farads. To extract column j, impose a declared test potential on node j, hold the other nodes at their stated reference values, and integrate signed free charge on each conductor. Divide the charges by the test potential.
Distinguish Maxwell charge coefficients from positive branch capacitances. In a reciprocal lumped branch network the Maxwell off-diagonals are nonpositive, and removing the grounded row and column retains capacitance to that reference.
Do not place positive branch capacitances directly into the off-diagonals of q = C v. In a positive lumped-capacitor network, a branch c_ij contributes +c_ij to both associated diagonals and −c_ij to both off-diagonals. A branch to the removed ground contributes only to the retained diagonal.
Use reciprocity as a separate check
Under the declared reciprocal electrostatic assumptions, C_ij = C_ji. Smolić and Klajn derive a symmetric volume-integral representation and examine the role of bounded domains, exterior regions and reference removal. Their analysis explains why a row-sum statement needs its domain and reference conditions. [1]
Compare the two independently extracted cross coefficients before modifying the matrix. A mismatch can arise from inconsistent node order, charge normal orientation, geometry, material state or numerical error. Symmetry is a useful test of the extraction; it does not prove that omitted end fields or a coarse section partition are accurate.
For reporting, one possible normalized residual is ||C − Cᵀ||_F / ||C||_F for a nonzero matrix. Set the tolerance from numerical convergence, units and the required observables, and retain the raw matrix before symmetrization.
Derive a complete assumed three-node matrix
Take positive hypothetical branches c_12 = 30 pF, c_1g = 10 pF and c_2g = 20 pF. Node order is 1, 2, g. These values are selected to audit the algebra, not extracted from a transformer.
The full Maxwell matrix, in pF, is:
C_full = [[40, −30, −10], [−30, 50, −20], [−10, −20, 30]]
Every row sums to zero. Since the matrix is symmetric, every column also sums to zero. Consequently C_full times the all-ones vector is zero, and the sum of all three charges is zero for any voltage vector in this declared closed network.
At v = [1,000, 1,000, 1,000] V, all three charges vanish. There is no branch voltage. This verifies a common-potential shift of the complete represented system, including the reference conductor.
Remove the grounded conductor without removing its capacitances
Now fix v_g = 0 and retain only nodes 1 and 2. Removing the reference row and column gives:
C_reduced = [[40, −30], [−30, 50]] pF
Its row sums are 10 and 20 pF. They equal the respective ground-branch capacitances in this particular network. They should not be forced to zero.
At v_1 = v_2 = 1,000 V, q_1 = 10 nC and q_2 = 20 nC. The interwinding branch carries no charge, but both ground branches do. Recover the omitted reference charge as q_g = −30 nC, so complete charge balance remains satisfied.
| Assumed state, volts | q_1 | q_2 | q_g | Stored energy |
|---|---|---|---|---|
| [1,000, 1,000, 1,000] | 0 | 0 | 0 | 0 |
| [1,000, 1,000, 0] | 10 nC | 20 nC | −30 nC | 15 µJ |
| [1,000, 0, 0] | 40 nC | −30 nC | −10 nC | 20 µJ |
Equal retained-node voltages are therefore not the same test as equal voltages on every conductor.

Check energy and locate an inconsistent entry
The declared network stores W = ½ Σ c_ij(v_i − v_j)², summing each positive branch once. Equivalently W = ½ vᵀ C_full v. This is nonnegative, and vanishes under a complete common-potential shift. With a connected network and fixed ground, the reduced quadratic form is positive for any nonzero retained voltage vector.
For this reduced matrix, the leading diagonal is 40 pF and the determinant is 1,100 pF², confirming positive definiteness of the symmetric two-node example. The full matrix is singular by design because its common-potential mode carries no energy; that singularity is not an extraction failure.
Suppose one cross entry is reported as −29 pF while its reciprocal remains −30 pF. The result fails symmetry. Averaging those entries alone changes both row sums and implied ground branches. Determine whether the error belongs to extraction, bookkeeping or a proposed fitting correction before rebuilding the diagonal; preserve any revised physical assumptions explicitly.
Release the matrix with its charge ledger
Deliver node order, included conductor surfaces, reference potential, charge sign, units, material assumptions and extraction conditions with both raw coefficients and residual checks. State whether coefficients are total capacitances or per-length values.
Repeat extraction with appropriate mesh and boundary-domain changes, then compare the chosen port or internal-voltage observable. Retain reciprocity, charge-balance and energy checks alongside that convergence evidence, with the broadband model’s remaining internal-structure assumptions stated explicitly.
Smolić and Klajn derive the conductor charge–potential matrix with its reference and domain conditions. Preserve that reference when interpreting charge, energy and any reduced network. [1]
Gustavsen and Heitz show that fitted multiport accuracy depends on terminal conditions and the visibility of small modes. Validate the response used for the engineering decision under its actual terminal loads. [2]
References
[1] I. Smolić and B. Klajn, Capacitance Matrix Revisited, 2021, DOI:10.2528/PIERB21011501.
[2] B. Gustavsen and C. Heitz, Modal Vector Fitting: A Tool for Generating Rational Models of High Accuracy with Arbitrary Terminal Conditions, 2008, DOI:10.1109/TADVP.2008.927810.