Why Thick Pressboard Dries from the Surface Inward

  • Chenfan Power

The surface of a thick pressboard part can dry while its centre remains wetter. Heating and chamber pressure set removal boundaries; water must still travel from the interior. Betie and colleagues describe the one-dimensional Fick model and its constant-diffusivity slab solution [1].

Why Thick Pressboard Dries from the Surface Inward: technical review table
First article table, reproduced without adding or changing values. See the article for assumptions and application boundaries.

Use thickness to identify the difficult part

For a simple homogeneous slab, a diffusion model is ∂c/∂t = D∂²c/∂x², where c is moisture content on a consistent kg-water/kg-dry-material basis for this homogeneous illustration, x distance in metres, time t seconds and D diffusivity in m²/s. A characteristic time scales with ℓ²/D, where ℓ is the relevant travel distance to an exposed surface.

At unchanged D and boundary conditions, doubling that distance increases the characteristic scale fourfold. This illustrates thickness sensitivity; it is not a factory cycle-time rule. Real D can depend on temperature and moisture, and a covered face can change the travel distance from half thickness to an edge path.

An oil or gas observation cannot resolve the centre concentration in the unequilibrated slab below. Preserve the solid-material sampling region and its temperature when comparing moisture evidence. [2]

Recompute the thickness time scale

For an independent ideal slab calculation, assume uniform initial moisture 2.0% of dry mass, both broad surfaces instantly held at 0.10%, fixed temperature and constant D = 1×10⁻¹⁰ m²/s. At t = 10,000 s, half-thickness ℓ = 1 mm gives Fo = Dt/ℓ² = 1; ℓ = 2 mm gives Fo = 0.25. The centre solution is (c−cs)/(c0−cs) = (4/π)Σ[(-1)ⁿ/(2n+1)]exp[−(2n+1)²π²Fo/4]. Summing the series gives centre moisture 0.305% and 1.402%. Against an assumed 0.50% centre criterion, only the thinner slab passes this ideal screen although both surfaces read 0.10%. At 40,000 s the thicker slab reaches the same 0.305%. Validate D, actual temperature/moisture dependence and exposed paths before setting a factory duration.

Compare measurements by depth and boundary

EvidenceWhat it describesWhat remains unresolved
Surface temperatureAccessible thermal boundaryCentre temperature during heating or evaporation
Chamber pressure/dew pointGas removal environment at the sample pointMoisture remaining deep in pressboard
Thin witness couponThat coupon’s removal responseThicker or shielded component response
Representative internal evidenceDefined depth or validated model estimateOther geometries outside the demonstrated scope

Identify the thickest and most shielded insulation in the load, not just the largest visible part. Record whether its broad faces are exposed, clamped or bonded. Those boundaries can matter as much as nominal thickness.