Chenfan Electric
EN
Send drawing

ARTICLETechnical article

First-Order Reversal Curves for Preisach Models of Transformer Steel

  • Chenfan Power

Identify a Preisach model with reversal histories that expose its memory behavior. A first-order reversal family adds information beyond one outer loop when the sampling, derivative processing and material conditions support the intended prediction.

Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.

Choose reversal coverage for the histories the model must reproduce. Preserve noise, conditioning differences and departures from classical behavior in the review rather than selecting curve count as the acceptance measure.

Specify the reversal family before acquiring it

Use an explicit convention. Start from a reproducible positive reference state, reduce field to reversal level H_r, then increase field H from H_r back toward the positive reference. Store magnetization M(H, H_r), or a clearly defined alternative output, together with the ordered trajectory. Repeat the preparation for each reversal level.

Ruta and colleagues’ original FORC study describes this saturation–descent–return protocol and the distinction between raw reversal data, a differentiated FORC diagram and its interpretation as a Preisach distribution. Their application concerns granular recording media. The protocol is useful methodological evidence; its particle parameters and field increments are not transformer-steel settings.

For a transformer-steel specimen, declare direction relative to rolling, specimen and magnetic-circuit geometry, stress state, temperature, conditioning, field derivation and excitation rate. Establish that the chosen reference state is reproducible within the intended measurement range. Do not call a limited high-field endpoint saturation merely because all acquisition runs finish there.

Choose reversal coverage around the histories the model will predict. A uniform grid is easy to process, but a denser grid near strong variation may be more informative. Retain sufficient neighboring curves and field points for the selected derivative estimator. Any adaptive sampling needs its actual coordinates preserved; a formula for a uniform grid cannot be silently applied to uneven spacing.

Define the distribution and its normalization

For this article, let m = M/M_s, where M_s is a separately defined saturation normalization. In the interior of the sampled domain H > H_r, define the normalized FORC density as:

ρ(H, H_r) = −½ ∂²m / (∂H ∂H_r)

This convention matches the magnetization normalization used in Ruta and colleagues’ formulation. Its units are inverse field squared. A density derived from unnormalized M has a different scale; an implementation fitted directly to B must declare its own output and normalization rather than borrowing an M-based amplitude unchanged.

A FORC diagram is not automatically a map of actual independent microscopic switching units. That interpretation depends on the model assumptions. General hysteretic systems can depart from them, and the cited original study demonstrates limitations in correlated granular systems. It supplies no numerical error bound for transformer steel.

Differentiation can dominate the identification error

Second-order differentiation magnifies noise in the measured reversal grid. Retain raw curves, derivative settings and smoothing sensitivity, then validate the fitted response on histories held back from identification.

Its practical lesson is to retain the transformation history. Keep raw data, interpolated data, derivative settings, regularization constraints and reconstructed curves. If nonnegative weights are imposed, preserve the required corrections and residuals. Removing negative regions can be a model constraint; it does not prove that the original observations were faulty or that the constrained model captures every mechanism.

An original local arithmetic example illustrates the derivative sensitivity. Take equally spaced interior coordinates H = 40, 60 A/m and H_r = −40, −20 A/m. A deliberately artificial local function gives the following dimensionless m values:

H_rm at H = 40 A/mm at H = 60 A/m
−40 A/m0.2920.328
−20 A/m0.3160.344

The mixed difference is 0.344 − 0.316 − 0.328 + 0.292 = −0.008. Dividing by 20 × 20 (A/m)² and multiplying by −½ gives ρ = 1.00 × 10⁻⁵ (A/m)⁻². Increasing only the upper-right m value by 0.001 changes the estimate to 8.75 × 10⁻⁶ (A/m)⁻², a 12.5% decrease.

These are test numbers for derivative code, not measured steel data, a complete physical reversal family or an uncertainty budget. The calculation explains why small point changes can matter after differentiation.

Reversal preparation and two-field data flow into reconstruction and independent memory tests, beside a four-point derivative sensitivity example.
An original identification and validation map, with a controlled reversal protocol and an artificial four-point derivative check. No measured FORC density, steel hysteresis curve or numerical material-performance claim is represented.

Test memory assumptions with separate trajectories

Classical Preisach interpretation relies on wiping-out and congruency properties. Test these against the intended model and specimen instead of declaring them satisfied because the fitted distribution looks smooth.

For a nested history, return to a previously visited extremum and compare the subsequent response with the appropriate reference history. Then exceed the earlier enclosing extremum and check the model’s predicted removal of nested memory. Specify which states and branches should coincide under the selected formulation. A single equal endpoint is weaker evidence than agreement over the relevant continuation.

For congruency, compare loops between the same reversal levels after different enclosing histories, using the model’s declared comparison convention. Inspect both shape and any allowed offset. Failure beyond the measurement comparison capability is evidence of a restricted model range or a need for a different formulation, not an instruction to smooth harder.

Also check return to the reference state and closure of declared repeated cycles. Drift may come from conditioning, rate, temperature, instrumentation or actual material behavior. Record it before deciding which explanation applies.

Reserve an independent minor-loop challenge

Hold back biased and nested reversal histories that were not used to select the distribution or smoothing strength. Compare the complete ordered response, reversal behavior and relevant closed-cycle energy where the measurement and model support it. Establish acceptance criteria for the intended prediction and measurement capability, rather than using an arbitrary percentage.

Release the scalar fit with its tested direction and rate, measured reversal family, processing settings, reconstruction residuals, memory tests and held-back predictions. Use separate evidence for multidirectional joint behavior, dynamic losses and assembled-core performance.

Size the reversal-curve specimen from a documented grade

Assume a 100 mm × 100 mm sheet specimen using the catalog 0.23 mm thickness and 7,650 kg/m³ density. [1] Its steel mass is 17.595 g. At the catalog M-3X sinusoidal reference of 1.7 T and 50 Hz, 0.453 W/lb corresponds to 17.572022 mW for that mass. This establishes a material-scale power check for the specimen and instrument planning. It supplies no FORC distribution: the reversal grid still requires ordered conditioned measurements and a derivative/noise study such as the local calculation above.

Preserve rolling direction, cut-edge condition, specimen stress, demagnetization history and any approved annealing. A FORC fit from one prepared strip cannot be assigned to a clamped step-lap junction without validating the changed material and field path. IEC 60404-8-7 provides the delivery-specification framework for fully processed grain-oriented steel. [2]

Ruta and colleagues show limitations of inferring intrinsic hysteron parameters from FORC distributions in correlated systems. Validate the fitted model on held-back magnetic histories. [3]

References

[1] Cleveland-Cliffs, Grain-Oriented Electrical Steels — LITE CARLITE and Mill-Anneal, October 2023, Tables 1 and 5; Stress-Relief Annealing.

[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.

[3] S. Ruta et al., First Order Reversal Curves and Intrinsic Parameter Determination for Magnetic Materials; Limitations of Hysteron-Based Approaches in Correlated Systems, 2017, DOI:10.1038/srep45218.

Chenfan Electric

Direct coordination

Start a conversation.

A drawing, a material requirement, or a project to discuss.

Send drawing