Separate the datum transformation from the physical state change when core suppliers report different packet dimensions. A free stack and a restrained assembly can differ through both reference position and compression or relaxation; document those contributions independently before comparing acceptance values.

Retain the original measurement definitions
For each critical feature, record the physical origin, direction, contact points, support, restraint and time relative to assembly or unloading. Preserve raw readings and the method. A number with no measured state cannot be translated reliably to a common drawing requirement. [1]
| Comparison element | Reconciliation method | Limit |
|---|---|---|
| Different coordinate origins | Verified translation between physical references | Requires a known reference relationship |
| Different axes or viewing direction | Defined rotation/sign convention | Must preserve feature identity |
| Free versus restrained state | Representative state-change measurements | Not corrected by coordinate algebra alone |
| Different probe/contact method | Matched-method comparison and uncertainty | Contact influence can change the measured quantity |
Apply coordinate arithmetic to coordinates
Keep the datum relationship’s uncertainty in the translated result. Where measurements share a reference or correction, account for correlation rather than treating every term as independent.
Measure the state transition separately
Compare consequential dimensions under the specified supports and restraint. Do not borrow a generic compression factor to translate every packet. Local contact, stack distribution and assembly history can make one measured transition unsuitable for another feature.
Close the drawing-to-inspection relationship
Define which state and datum the acceptance dimension actually requires, then connect each supplier’s method to it using supported transformations and checks. If the drawing remains ambiguous, obtain its engineering disposition before turning a measurement difference into a supplier nonconformity.
Keep the datum offset separate from packet compression
The catalogue nominal gauge is 0.23 mm [2]. Assumptions: 500 sheets, a feature reading of 300 mm above datum A, datum B 20 mm above A, and measured packet heights of 116.5 mm free and 116.0 mm restrained. Steel-only height is 115 mm; the coordinate is 300 − 20 = 280 mm above B, while the measured restraint change is 0.5 mm. Subtracting 20 mm cannot correct that physical state change. Retain the two transformations separately, with their measurement uncertainties and any shared-reference covariance [3].
Gauge distribution, inter-sheet gaps, support points and clamp load govern the measured state. Fix datum direction and probe contact before comparing suppliers.
Release the dimensional comparison with the original readings, supported coordinate transformations and independently measured state changes. Define the inspection datum and restraint condition for repeat receiving measurements, and obtain the missing transition evidence wherever an unresolved interval affects acceptance.
References
- NASA, NASA Systems Engineering Handbook, section 6.5, Configuration Management, official online text.
- Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, catalogue D004je, April 2020, specification tables, size tolerances and Annealing by Customers.
- B. N. Taylor and C. E. Kuyatt, NIST Technical Note 1297, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, 1994, sections 5 and 6.