Interleaved Disc Windings: Derive Series Capacitance from the Connection Map

  • Chenfan Power

Derive interleaving’s energy-equivalent series capacitance from the connection map. Electrically distant neighbors can carry larger voltage differences across similar local capacitances, changing their energy contribution and the interfaces that control the insulation check.

Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.

The required engineering artifact is a map that identifies both physical neighbors and their positions in the winding’s electrical sequence.

Keep physical order separate from electrical order

Number conductor groups in their electrical sequence from the start to the finish of the analyzed section. Then place those numbers on the physical cross-section. An adjacent pair on the drawing can be several electrical steps apart after interleaving.

For every represented capacitive interface, record its two electrical labels and its capacitance. Retain crossovers, insulation distances, group boundaries and connections to other discs. If those details change between constructions, the capacitance values can also change; the topology and geometry contributions should be evaluated separately.

A simplified calculation may prescribe a voltage progression along the electrical sequence. State that progression explicitly. A real transient distribution must be obtained from the coupled model and boundary conditions rather than inferred from conductor numbering alone.

Use the electrostatic energy definition

For pair capacitances c_ij and a prescribed voltage vector v, the represented energy is:

W = ½ Σ_(i<j) c_ij(v_i − v_j)².

For an applied section voltage V, define the energy-equivalent quantity C_E = 2W/V². A grounded Maxwell matrix expresses the same electrostatic energy as ½vᵀCv. Preserve the voltage profile used to define that equivalent.

The voltage profile belongs to C_E’s definition. Changing the imposed profile can change the equivalent value even if the local pair capacitances stay fixed. A profile-based series-capacitance estimate and a measured terminal capacitance under a different condition are therefore different quantities.

Compare two original four-group arrangements

Let electrical labels 0, 1, 2 and 3 have prescribed potentials 0, V/3, 2V/3 and V. Include only the three capacitances between physically neighboring groups, each c = 100 pF. Ignore ground capacitance and distant neighbors to isolate the ordering effect.

In the ordinary physical order [0, 1, 2, 3], each interface has a voltage-difference magnitude V/3. The energy is:

W_ord = ½c[3(V/3)²] = cV²/6.

Thus C_E,ord = c/3 = 33.333 pF.

In the illustrative interleaved physical order [0, 2, 1, 3], the signed voltage differences across successive interfaces are 2V/3, −V/3 and 2V/3. Squaring and summing gives:

W_int = ½c[(2V/3)² + (−V/3)² + (2V/3)²] = ½cV².

Thus C_E,int = c = 100 pF. The energy-equivalent capacitance is three times larger in this particular construction and prescribed profile.

At V = 1 kV, the energies are 16.667 µJ and 50.000 µJ, respectively. The two larger interleaved interfaces each store 22.222 µJ, while the middle interface stores 5.556 µJ. Those local energies reveal where the increase comes from.

Ordinary and interleaved physical conductor orders with fixed electrical-label potentials and a threefold prescribed-profile energy-equivalent capacitance comparison.
Original four-group ordering and energy calculation. Electrical labels retain their prescribed potentials while physical adjacency changes. The threefold energy-equivalent increase applies to this profile; a floating-node terminal-capacitance experiment gives a different result.

Check what the equivalent value represents

The factor of three above is an exact result for the stated pair-capacitance graph and imposed electrical voltage progression. Recompute the ratio for the actual pair-capacitance graph and voltage distribution.

To see the importance of the profile assumption, instead treat the two internal groups as floating electrostatic nodes, impose only 0 and V at the two ends, and allow their potentials to equilibrate through the three neighbor capacitances. Both arrangements then form three equal capacitors in series between the physical endpoints, giving a terminal capacitance c/3. In that different experiment, the internal potentials follow physical charge balance rather than the prescribed electrical sequence.

A winding has inductive, resistive and capacitive dynamics that determine its instantaneous turn potentials. Use the profile-based energy calculation as a derived parameter under its stated winding-model assumptions, then check those assumptions against the intended transient response.

Evaluate local insulation and the complete network

An increase in equivalent series capacitance does not by itself establish lower voltage across every local interface. The interleaved example deliberately raises the voltage difference across two neighbors from V/3 to 2V/3. Insulation and crossover geometry must be evaluated against those local differences.

Add relevant turn-to-ground, disc-to-disc and distant-neighbor capacitances to the complete network. Include the inductance matrix and losses for time-domain analysis. Compare the two winding arrangements under the same applied waveform, grounding, terminal loads and parameter basis.

Retain both the derived equivalent quantity and the local maxima that control the design. A single larger capacitance number cannot replace the connection map or the internal-voltage assessment.

Make the supplier calculation reviewable

A useful design exchange includes the electrical sequence, physical adjacency map, local capacitance assumptions, voltage profile, energy sum and resulting equivalent capacitance. If a claimed increase comes from altered spacing or insulation, show that contribution separately from the ordering effect.

Report the adjacency and voltage-profile contributions to the equivalent capacitance, alongside the local interfaces carrying the largest differences. Keep that calculation with the winding designer’s complete-network and transient checks so the customer can reproduce the stated increase.

Smolić and Klajn derive the conductor charge–potential matrix with its reference and domain conditions. Preserve that reference when interpreting charge, energy and any reduced network. [1]

Gustavsen and Heitz show that fitted multiport accuracy depends on terminal conditions and the visibility of small modes. Validate the response used for the engineering decision under its actual terminal loads. [2]

References

[1] I. Smolić and B. Klajn, Capacitance Matrix Revisited, 2021, DOI:10.2528/PIERB21011501.

[2] B. Gustavsen and C. Heitz, Modal Vector Fitting: A Tool for Generating Rational Models of High Accuracy with Arbitrary Terminal Conditions, 2008, DOI:10.1109/TADVP.2008.927810.