Chenfan Electric
EN
Send drawing

ARTICLETechnical article

Uncoiler Inertia Compensation During Narrow-Strip Acceleration

  • Chenfan Power

Update uncoiler torque compensation as the coil radius and inertia change. During acceleration, strip tension contributes to the torque that accelerates the roll; a model based only on steady resisting torque leaves that extra demand in the strip.

Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.

For a driven uncoiler, update the shaft-referred inertia model and verify its acceleration response against independent tension evidence. Set the actual CRGO force limits and drive conditions from the qualified material and line requirements.

Update the roll and fixed rotating parts separately

For an original idealized model, treat the remaining material as a uniformly filled annular cylinder with outer radius R, inner radius r, width b and effective density ρ. Its mass is m = πρb(R² − r²) and its axial rotational inertia is J_roll = ½m(R² + r²). The latter follows from integrating radius squared over the annular mass, rather than placing all material at the outer radius.

Add the mandrel and other rotating inertias on the same shaft reference. If a motor or gearbox is on another speed reference, apply the correct gear-ratio transformation before summing. Do not mix drive-side inertia with roll-side angular acceleration.

Siemens’ original SIMATIC Winder and Tension Control manual separates material inertia, mandrel inertia, motor/fixed inertia, diameter, width, density, fill factor and gear ratio. Its torque-precontrol block also distinguishes acceleration, changing diameter, friction and tension terms. Use those terms to reconcile the actual line’s torque model and identified parameters.

Coil diameter should be a verified state estimate. A thickness-based calculation, speed/revolution ratio or external measurement has different validity conditions. A diameter number remaining plausible after strip slip or an incorrect initial state is not proof that the inertia model is correct.

Declare the unwinding sign convention

Let positive rotation be the unwinding direction. Strip tension T applies positive torque TR. Positive motor torque τ_m assists unwinding, while a resisting loss torque τ_loss acts negatively. A short-window, frozen-radius balance is:

Jα = TR + τ_m − τ_loss.

For target tension T* and modeled inertia J_hat, an ideal feedforward torque is τ_m = J_hat α − T*R + τ_loss. Substitution gives T − T* = (J − J_hat)α/R, assuming the loss estimate is exact and the motor delivers the requested torque.

This sign matters. During acceleration the required motor contribution can change from braking to assisting the roll. A passive brake cannot deliver a positive assisting torque; it is a different actuator problem. Rewinding, opposite winding geometry and another shaft convention require their corresponding signs. Copying a compensation magnitude without its direction can worsen the disturbance.

With R approximately constant over the short interval, α = a/R for strip acceleration a. Thus the inertia-error contribution is ΔT = (J − J_hat)a/R². These are conditional instantaneous balances, not closed-loop transient waveforms.

Compare two hypothetical coil states

Assume b = 0.10 m, r = 0.10 m, effective density ρ = 7,650 kg/m³ and fixed shaft-referred inertia of 0.8 kg·m². Effective density includes the assumed fully filled annulus; real packing, coatings, gaps and geometry would need the appropriate effective model. Assume unity gear ratio, no losses, target tension 50 N and acceleration 1.0 m/s². All parameters are assumed for illustration.

StateR, mMaterial mass, kgTotal J, kg·m²α, rad/s²Inertial torque Jα, N·m
Larger roll0.40360.49831.4422.578.606
Smaller roll0.2072.1002.6025.013.012

Without inertia assistance, suppose the motor retains only the steady resisting torque −T*R. The conditional tension becomes 50 + J a/R²: 246.514 N for the larger roll and 115.062 N for the smaller roll. The excesses, 196.514 N and 65.062 N, are calculated model contributions, not measured overshoot or approved strip forces.

With exact ideal inertia feedforward, the motor torques are 78.606 − 20 = +58.606 N·m and 13.012 − 10 = +3.012 N·m. The model then retains 50 N tension. It does not prove that a real drive has the needed torque, power, response or stability.

Two hypothetical annular roll states and conditional acceleration torque table with declared positive unwinding motor-assist convention.
Original instantaneous balance illustration at two hypothetical radii. Values are model contributions under declared assumptions, not measured tension transients or approved strip forces.

The material inertia falls sharply with radius, but the fixed 0.8 kg·m² remains. Near the inner radius, ignoring that fixed term becomes proportionally more important. A fixed full-coil compensation is therefore not an acceptable replacement for updating the model through the coil state.

Separate feedforward error from feedback behavior

Feedforward anticipates a known inertial demand. Feedback responds to an observed or estimated tension error. The Siemens manual describes load-cell feedback and torque-derived indirect tension methods separately, and notes the importance of friction/acceleration compensation for the latter.

A torque-derived tension value is not an independent measurement validating the same torque/inertia model used to calculate it. Where suitable equipment provides a load-cell signal, retain its calibration, location and dynamics when comparing the two. A dancer adds another dynamic element and buffer; its motion cannot be assumed equivalent to instantaneous strip tension.

The frozen-radius illustration omits the radius-change contribution. When it is significant, differentiating ω = v/R gives α = a/R − vR_dot/R². Siemens’ implementation explicitly includes a separate diameter-change contribution. Actual material transport, elasticity, friction, eccentricity, drive saturation and sensing/control delays also need the appropriate model. Do not extend the simple equation to slack strip or an actuator that cannot realize its required torque.

Verify the acceleration segment directly

Under approved operating conditions, retain diameter estimate, speed and acceleration, modeled inertia, requested/actual motor torque, target tension and available independent tension evidence. Include both acceleration and deceleration and representative full-to-small roll states. Mark torque limiting and invalid sensor intervals rather than discarding them.

Align signals to the same time reference. Compare peak deviation, duration, settling and recurrence using an agreed definition and measurement bandwidth. Do not report a calculated inertia-error term as an experimentally observed peak.

Validate compensation across the measured acceleration and deceleration segments. Identify the state estimate or torque term responsible for each disturbance, and retain the evidence that the complete permitted route remains acceptable through the coil’s operating range.

Use catalog density with an explicit winding-pack assumption

The 7,650 kg/m³ value used above is the catalog’s assumed steel density. [1] The roll calculation separately assumes a fully filled annulus with no void or coating-volume correction. With nominal 0.23 mm sheet, the calculated strip lengths are π(0.40² − 0.10²)/0.00023 = 2048.865 m and π(0.20² − 0.10²)/0.00023 = 409.773 m. Multiplying by the assumed 100 mm width, thickness and density reproduces the two steel masses in the inertia table. Check actual roll packing and shaft inertia before using those lengths to schedule the compensation update.

Control measured roll radius, strip width, gauge, pack tightness, brake/drive torque and feed acceleration. Excess tension can alter flatness and introduce stress before cutting; the compensation model must follow the actual coil rather than a fixed full-roll constant. IEC 60404-8-7 provides the delivery-specification framework for fully processed grain-oriented steel. [2]

References

[1] Cleveland-Cliffs, Grain-Oriented Electrical Steels — LITE CARLITE and Mill-Anneal, October 2023, Tables 1 and 5; Stress-Relief Annealing.

[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.

Chenfan Electric

Direct coordination

Start a conversation.

A drawing, a material requirement, or a project to discuss.

Send drawing