Transfer core loss to the thermal mesh with both watts and location intact. Different meshes, thin-sheet boundaries and bulk-stack averaging can lose, duplicate or relocate power unless the transfer carries an explicit regional ledger.
Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.
Treat the transfer as a separate numerical operation. Verify its power ledger before interpreting the resulting temperature field. A smooth interpolated source is not evidence that this ledger closes.
Decide what the exported values represent
Distinguish a cell-integrated loss in watts from a volumetric density in W/m³. For a piecewise constant source cell i, its power is P_i = q_i V_i. A raw sum of q_i values has no power meaning when cell volumes differ.
Preserving the sum of already integrated powers and preserving the volume integral of a density are different mapping contracts. State the exported quantity and integration weights before choosing a transfer operator.
Check the actual exported representation, discrete integration rule and mesh connectivity used in the thermal handover. Validate the transfer separately from the magnetic and thermal constitutive models.
Derive a transfer for declared cell averages
For an original piecewise constant construction, let O_ij be the volume shared by source cell i and target cell j. Assign target power and density as:
P_j = sum_i q_i O_ij; q_j = P_j / V_j
Here V_j is the volume on which the thermal solver actually applies q_j. The formula transfers integrated power rather than sampling the source at one target point.
If the target cells form a nonoverlapping partition covering every source cell, sum_j O_ij = V_i. Consequently, sum_j P_j = sum_i q_i V_i. This is a direct algebraic conservation result under the stated geometry and cell-average assumptions, not a result from a production finite-element model.
Higher-order fields need their own compatible integration or projection. The constant-cell construction does not specify a universal nodal transfer matrix, preserve arbitrary source gradients or reproduce the original peak density.
Recompute a small unequal-volume ledger
Use an assumed one-dimensional prism with a constant cross-section of 1 cm². Source A spans 0–4 cm and has q_A = 2 W/cm³; source B spans 4–10 cm and has q_B = 8 W/cm³. Their volumes are 4 and 6 cm³, giving powers of 8 and 48 W: 56 W in total.
The target split lies at 5 cm, producing two 5 cm³ cells. Target 1 overlaps all 4 cm³ of A and 1 cm³ of B, receiving 4 × 2 + 1 × 8 = 16 W. Target 2 receives 5 × 8 = 40 W. Their densities are 3.2 and 8 W/cm³.
In SI units, 1 cm³ = 10⁻⁶ m³ and 1 W/cm³ = 10⁶ W/m³. Both forms give the same watts. The deliberately high assumed densities illustrate arithmetic only; they are not credible operating loss data or a thermal design condition.
| Transfer in the assumed full prism | Target 1 power | Target 2 power | Total |
|---|---|---|---|
| Geometric overlap | 16 W | 40 W | 56 W |
| Source value at each target center | 10 W | 40 W | 50 W |
| Center sampling multiplied by 56/50 | 11.2 W | 44.8 W | 56 W |

The first target center lies within A, so center sampling misses B’s contribution there. Multiplying both sampled values by 1.12 restores total watts but leaves Target 1 30% below its overlap value and Target 2 12% above it. Global conservation alone cannot prove a correct local source distribution.
Account for clipped thin boundaries
For each source cell, calculate a coverage fraction c_i = sum_j O_ij/V_i. A value below one identifies uncovered source volume; a value above one indicates overlapping target support or a counting error in this construction. Equal overall model volumes do not establish local coverage.
In the same assumed prism, clip the target domain at 9 cm. The overlap method now transfers 16 + 32 = 48 W. The missing final 1 cm³ of B contains 8 W. Report full source power, covered source power, transferred power and omitted power separately.
Scaling the remaining 48 W to 56 W would redistribute omitted heat into the retained domain. It would conceal the geometric omission rather than repair it. Either restore the missing region or justify a different physical representation with an explicit source allocation.
For thin laminations, inspect intersections at sheet edges and interfaces rather than relying only on cell centers. An unresolved sliver can carry finite integrated loss even when no target sampling point falls inside it.
Keep steel volume and bulk-stack volume consistent
A density averaged over steel cannot be applied unchanged to a larger thermal region that includes insulation. Under an explicitly uniform local steel fraction k, with no source assigned to the nonsteel fraction, q_bulk = k q_steel preserves the steel-generated power over the corresponding bulk volume.
This is a volume allocation, not a thermal homogenization law. It does not determine anisotropic conductivity, interface resistance or the local position of sheet losses. If k varies spatially, use the represented steel volume in each receiving region rather than a single global multiplier.
Preserve the time convention too. A cycle-averaged magnetic source and an instantaneous source are different inputs. Mapping their spatial integrals cannot resolve a mismatch in averaging period or operating condition.
Release a local ledger with the total
Retain source and target physical domains, units, averaging convention, quadrature and coverage residuals. Compare regional power over joints, limbs and sheet-edge neighborhoods that matter to the intended thermal decision, with the same physical regions on both meshes.
For nonnegative loss averages, nonnegative overlap volumes also yield nonnegative receiving powers. Unexpected negative sources merit investigation of the exported quantity and projection; silently clipping them can alter the ledger. Reversible energy exchange must not be mislabeled as dissipative core loss.
Release the map with its covered-source, transferred and regional-power checks. Then validate magnetic loss, thermal material properties and cooling boundaries using their own evidence before interpreting a calculated hot spot.
Transfer a catalog-scale volumetric heat source
At the catalog M-3X condition of 1.7 T and 50 Hz, 0.453 W/lb equals 0.998694 W/kg. With catalog density 7,650 kg/m³, the equivalent steel-only source is 7640.009 W/m³. [1] An assumed 100 kg steel region occupies 0.01307190 m³ and generates 99.869 W. If its thermal mesh uses an assumed uniform steel fraction of 0.96, the bulk volume becomes 0.01361656 m³ and the applied bulk density must fall to 7334.409 W/m³. Both integrals then give the same power. Export steel volume and receiving bulk volume together; using the steel-only density over the larger bulk region overstates power by 4.167%.
Control lamination thickness, actual layer count, insulation/void volume and joint-region placement in the mesh handover. Cutting burrs, coating damage, gaps and clamping stress affect the magnetic source and need their own measured or validated correction; a conservative map only transfers the source it receives. IEC 60404-8-7 provides the delivery-specification framework for fully processed grain-oriented steel. [2]
References
[1] Cleveland-Cliffs, Grain-Oriented Electrical Steels — LITE CARLITE and Mill-Anneal, October 2023, Tables 1 and 5; Stress-Relief Annealing.
[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.