  • Chenfan Power

Preserve contact positions and complete return paths when modeling conductive lamination bridges. Two contacts between the same sheets can close a loop; collapsing them into one edge removes both that circulation and the geometry needed to calculate its flux linkage.

Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.

Reduce the network against the interlaminar circulation being investigated. Carry the positioned nodes, distinct contacts and electrical impedances into the reduction, then test whether its linked-flux response remains intact.

Place nodes at electrical locations

Use nodes for local conducting regions or connection locations. Connect them with edges representing retained along-sheet paths, cross-layer contacts and other included return routes. Give every bridge an identity, connected sheets, position and impedance model. Keep an observed contact distinct from a suspected contact.

Representing an entire sheet as one equipotential node is a strong reduction. It removes the voltage drop along that sheet unless the reduced model accounts for it elsewhere. Even when such a reduction is justified, two distinct contacts between two sheet nodes are parallel edges in a multigraph. Merging them into a single edge can erase a cycle and its physical linkage.

The original boundary-layer study by Shah and colleagues models interlaminar galvanic contact at burred edges and compares it with a finely resolved conducting-layer model. It explicitly identifies complete return paths and reports that the two representations do not agree uniformly across all examined conditions. That is evidence for retaining the actual conducting boundary and validating a reduction, rather than treating bridge count as a loss model. [3]

Identify cycles within the declared network

For an undirected network with N nodes, M edges and c connected components, the number of independent graph cycles is β = M − N + c. This counts independent topological cycles; it does not specify their linked flux, current or temperature.

Consider four local nodes: left and right positions on each of two initially separate sheets. Retain one along-sheet edge on each sheet. With only one bridge joining the left positions, the network has N = 4, M = 3 and c = 1, so β = 0. Adding a second bridge at the right positions gives M = 4 and β = 1. The new loop contains both sheet segments and both bridges.

That first result means no additional cross-sheet cycle in this declared network. It does not exclude ordinary distributed eddy currents inside either sheet. It also does not apply when a continuous wound strip, an existing connection or another included conductor already supplies a return. Those routes must be represented before cycle counting.

If the two along-sheet edges are contracted, the two contacts remain separate parallel edges between two nodes. Then N = 2, M = 2 and c = 1 still give β = 1. A simple graph that merges both contacts into one edge instead gives β = 0 and loses the circulation being investigated. Preserve the edge identities and geometry when reducing the network.

Original four-node conductive bridge graph and contracted parallel-edge multigraph with a separate hypothetical loop-area and resistive-loss comparison.
Original positioned contact graph and cycle-preserving contracted multigraph. A separate assumed rectangular-loop calculation keeps contact count fixed while varying prescribed loop area; electromagnetic linkage and impedance remain necessary.

Supply flux linkage as well as connectivity

For each oriented loop, Faraday’s law gives its induced electromotive force from the rate of change of linked magnetic flux. Geometry determines the surface and its orientation; a field model or a justified prescribed-field assumption supplies the flux. A graph without this information can enumerate connections, but cannot calculate induction-driven current.

Bridge location, loop orientation, return geometry and resistance must be retained with contact count. Use the complete path to calculate induced voltage and loss under its declared field; obtain contact parameters from the actual stack.

Retain finite impedances along steel paths and at contacts. For multiple cycles sharing an edge, do not compute isolated-loop losses and simply add them. Their branch currents interact. In a linear network with no external current injections, a cycle-basis matrix C can express branch currents as i = Cj. If R is the diagonal branch-resistance matrix, resistive loss is jᵀCᵀRCj. Shared-edge terms belong in that expression. Inductance and magnetic feedback require the corresponding coupled impedance or field treatment.

A location-sensitive example with the same contact count

Take two assumed bridges between two parallel sheet paths. Their center-plane separation is d = 0.30 mm, and their in-plane separation is s. Approximate the enclosed loop as a rectangle of area A_loop = d s. Prescribe a uniform sinusoidal magnetic field normal to that rectangle with B_RMS = 0.50 T at 50 Hz.

Assign the same total loop resistance, R = 0.10 Ω, in both comparisons. Neglect inductive impedance, field reaction, skin effects and dielectric paths. These choices isolate the effect of assigned loop area; they are not contact-resistance measurements or typical lamination values.

E_RMS = 2πf B_RMS A_loop,

I_RMS = E_RMS/R, and P = E_RMS²/R.

Bridge separation, sLoop areaInduced RMS voltageRMS currentAssigned resistive loss
50 mm15 mm²2.356 mV23.562 mA0.05552 mW
200 mm60 mm²9.425 mV94.248 mA0.88826 mW

The graph has one independent loop and two bridges in both cases. Yet the assigned area increases fourfold and the resistive loss increases sixteenfold under the stated equal-resistance assumptions. In a real core, moving contacts can also change path resistance, field distribution and inductance. The sixteenfold result must therefore remain attached to this prescribed example.

Make the reduction auditable

A model handover should include the positioned nodes, distinct bridge edges, retained along-sheet and external paths, cycle basis, linked-flux definition and electrical parameters. Explain which paths were contracted and where their geometry, voltage drop and impedance went.

Check limiting cases before using the model: remove a bridge and confirm the intended cycle disappears; retain two distinct bridges and confirm their cycle survives contraction; change loop orientation and confirm the prescribed linkage responds consistently.

Use the graph to separate connectivity from electromagnetic drive. Link each retained cycle to its physical flux surface and impedance, then validate the reduction against the field resolution and assembly behavior required by the chosen observable.

Separate sheet-path resistance from bridge resistance

The catalog gives resistivity 51 × 10⁻⁸ Ω·m and nominal sheet thickness 0.23 mm. [1] Assume a 100 mm long, 10 mm wide in-plane current path. Its DC resistance is ρₑl/(wt) = 0.02217391 Ω. Two such sheet paths in a complete loop contribute 0.04434783 Ω before any contact resistance is added. Substituting a 0.27 mm catalog sheet under the same geometric assumptions lowers each path resistance to 0.01888889 Ω. Retain gauge and contact resistance as separate inputs; using one fitted loop resistance can conceal a changed conducting path.

Control sheared-edge burrs, insulation condition, contact location, sheet gauge and clamp pressure. Keep the two conducting contacts and their return geometry identifiable through any graph reduction. Bridge count alone cannot establish loop area or dissipated power. IEC 60404-8-7 provides the delivery-specification framework for fully processed grain-oriented steel. [2]

Shah and colleagues model galvanic contact at burred lamination edges using a boundary-layer representation. Retain the return path and validate the reduced conducting boundary against the intended conditions. [3]

References

[1] Cleveland-Cliffs, Grain-Oriented Electrical Steels — LITE CARLITE and Mill-Anneal, October 2023, Tables 1 and 5; Stress-Relief Annealing.

[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.

[3] S. Shah et al., Modeling of Losses Due to Inter-Laminar Short-Circuit Currents in Lamination Stacks, 2013, DOI:10.2478/ecce-2013-0012.

Chenfan Electric

Direct coordination

Start a conversation.

A drawing, a material requirement, or a project to discuss.

Send drawing