Check sleeve-end contact against the loaded seat geometry before assigning axial load. Carry the sleeve length, compressed washer dimensions and clamp spacing through the same reference state, then inspect the individual end clearances required by the drawing.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
The review starts with the actual seat geometry and the assembly state at which its dimensions apply. It ends with a contact decision: does the sleeve remain clear, deliberately carry an assessed end load, or prevent the intended seat spacing from being reached?
Define the intended function before calculating clearance
A sleeve surrounding a bolt is not automatically an unloaded component. Some designs can intentionally assign it a mechanical function; others require it to remain free of end compression. Use the approved detail to identify that function and the conductive parts it must separate.
For the specific geometry considered here, an insulating washer lies between each clamp face and an outer metal bearing seat. The sleeve passes through the washer holes. There are no counterbores, recessed seats or internal shoulders in the assumed axial chain.
Define h as the separation between the washer-supporting clamp faces in a stated assembly condition, and t_1 and t_2 as the corresponding loaded washer thicknesses. The distance between the two potential sleeve-end contact planes is:
H = h + t_1 + t_2.
Let L_s be the sleeve’s end-to-end length in that same reference condition. Its total available axial end clearance is:
g = H − L_s.
For this geometry, g > 0 means total end clearance, g = 0 marks first contact, and g < 0 means an overlength relative to the specified seat spacing. The last case requires sleeve compression, another geometric accommodation, or failure to reach that spacing. It does not alone demonstrate crushing.
This total clearance also does not guarantee clearance at both ends. Sleeve positioning, tilt and restraint can put one end against its seat while the opposite end holds all of g. Review the individual end locations where the design requires both ends to remain clear.
Calculate the contact threshold with the correct signs
Consider these entirely hypothetical dimensional limits, in millimetres:
| Dimension in the declared reference state | Nominal | Limit variation |
|---|---|---|
| Clamp-face separation h | 50.00 | ±0.10 |
| Loaded washer thickness t_1 | 1.00 | ±0.05 |
| Loaded washer thickness t_2 | 1.00 | ±0.05 |
| Sleeve length L_s | 51.80 | ±0.10 |
The nominal seat spacing is 52.00 mm and the nominal total clearance is 0.20 mm. Yet H can range from 51.80 to 52.20 mm, while L_s can range from 51.70 to 51.90 mm. A worst-case independent-limit screen therefore gives:
g_min = 51.80 − 51.90 = −0.10 mm;
g_max = 52.20 − 51.70 = +0.50 mm.
Every individual part can meet these assumed limits while the combined geometry crosses the first-contact threshold. This is an interval screen, not a probability of failure. Actual dependencies between dimensions, pairing rules or controlled adjustments can change the attainable combinations and must be documented if used to narrow the interval.

Keep assembly compression and later shortening separate
The washer dimensions in that example belong to the stated loaded reference condition. Substituting free-sheet thickness without accounting for seating or compression would change the question being answered.
Chambers’ original NASA Preloaded Joint Analysis Methodology for Space Flight Systems describes bolt elongation, compression of the clamped parts, thermal mismatch and preload relaxation through contact seating. Its joint-stiffness discussion also warns that the compressed region can be difficult to establish. These are relevant general mechanics, not evidence that a particular transformer sleeve has a known crush strength. [2]
Suppose additional stack shortening after the declared reference state reduces H by an assumed 0.08 mm while L_s remains unchanged. The nominal clearance becomes 0.12 mm, and the screened interval shifts to −0.18 to +0.42 mm. The example does not predict how much shortening an actual assembly will experience.
Do not subtract that same 0.08 mm if the h and washer-thickness limits already describe the final condition containing it. Define the reference state once, then record only subsequent changes. Thermal effects similarly require the change in H and the change in L_s; their difference changes g. Material names alone do not supply a defensible service-temperature clearance.
Contact changes the load path; interference does not supply a force
Once both sleeve ends contact their seats, further closure can introduce axial sleeve load. How much load enters the sleeve depends on its stiffness, end contact, the surrounding joint compliance and the achieved seat spacing. Tightening torque alone does not determine that distribution.
Even a simple sleeve spring relation needs qualifications. For a prescribed seat spacing and an assumed linearized sleeve stiffness k_s, one could write F_s approximately as k_s times the positive part of L_s − H. An actual bolted joint does not necessarily prescribe H independently: the sleeve, washers, clamps and bolt can all deform or alter contact. Solve or measure the coupled assembly when sleeve force matters.
Local end loading can also differ from uniform compression. An angled cut, chamfer, chipped edge or tilted seat changes the initially engaged area. A material coupon’s compressive strength does not identify an installed sleeve-end allowable load or establish retained electrical insulation.
Make the release evidence specific to the sleeve ends
Record the dimensions, their measurement state and the actual end-contact geometry. Confirm whether recesses, shoulders, washer steps or permitted sleeve movement change the chain. Check the accessible ends for indentation, cracks, lost edge material and displacement after the authorized assembly operation.
Use the electrical drawing to identify the required isolation boundary and retain the specified assembled verification. A contact mark is evidence of contact, not proof of a short; an undamaged visible end does not prove every hidden interface is sound.
Verify unloaded sleeve ends with the required individual clearances in each applicable assembly state. For an intentionally loaded sleeve, qualify end contact, deformation and electrical separation against the approved joint detail.
Check whether a sheet-count change closes the sleeve clearance
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume clamp-face separation follows the packet build one-for-one, with all other dimensions fixed. A one-sheet increase adds 0.23 mm to H and to total sleeve-end clearance g. A one-sheet decrease subtracts 0.23 mm. Starting from the assumed 0.20 mm nominal clearance, the latter produces −0.03 mm and changes the sleeve from clear to contacting. Reconcile packet count and loaded build before accepting the sleeve length.
Manufacturing controls. Control sheet count, assembled compression, loaded washer thickness, sleeve squareness and differential thermal movement. The bolt/member stiffness and contact seating determine what happens after contact begins. [2]
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] J. A. Chambers, Preloaded Joint Analysis Methodology for Space Flight Systems, NASA TM-106943, 1995.