Preserve the phase when using complex permeability. A purely real magnitude can retain the prescribed-field flux amplitude while removing the magnetic cycle loss carried by the original coefficient.
Calculation basis. Unless a value is explicitly attributed to a cited source, numerical inputs in the demonstrations are assumptions for the stated model. Normalized variables are dimensionless. The examples define their own geometry, excitation and measurement boundary.
Use the real and loss components together under a declared phasor convention and operating condition. Check the resulting energy, rather than judging a replacement only by the amplitude of B.
State the linearized operating condition
A scalar frequency-domain relation B̂ = μ₀μ_rĤ describes a specified direction and harmonic operating condition. Here hats denote phasors, μ₀ is vacuum permeability and μ_r is relative permeability. The scalar representation must be justified for the material direction and excursion being studied.
Record frequency, amplitude, bias, temperature, specimen or effective-core boundary and the definition used to obtain μ_r. A small-signal value around a bias, an effective large-excursion value and an initial-permeability value are different inputs.
An ordinary single-frequency phasor relation assumes linear harmonic fields at the stated operating point. Effective nonlinear coefficients require a declared fitting condition; preserve waveform, bias and directional scope.
If an effective parameter is fitted to a particular periodic response, preserve that fitting condition. Do not quietly extend it to another waveform, field direction or frequency.
Fix the sign convention explicitly
Use the time dependence Re{Ĥe^{jωt}}. With this convention, a scalar lossy permeability is written
μ_r = μ′ − jμ″, with μ″ ≥ 0 for the assumed passive scalar loss model.
The complex number’s mathematical imaginary part is −μ″. The named positive loss parameter μ″ is not itself the signed imaginary part returned by a numerical imaginary-part function.
With the chosen e^{jωt} convention, entering μ′ − jμ″ with positive μ″ gives positive cycle work for this scalar passive model. Conjugate coefficients consistently when exchanging data with an opposite time convention.
If the time convention instead uses e^{−jωt}, transform the coefficient consistently. Moving a signed complex number from one convention to the other without that transformation can turn intended loss into apparent gain.
Retain phase in the time-domain relationship
Choose Ĥ = H_pk as a real positive peak amplitude. The corresponding real fields are
H(t) = H_pk cos(ωt)
B(t) = μ₀H_pk[μ′ cos(ωt) + μ″ sin(ωt)].
Thus B lags H by δ = atan2(μ″, μ′) when both components are positive, and its peak amplitude is μ₀H_pk√(μ′² + μ″²). This is a declared linear scalar harmonic model, not a measured hysteresis loop of electrical steel.
The phase lag and amplitude come from the same complex coefficient. Keeping only √(μ′² + μ″²) preserves the amplitude for this prescribed H but makes the coefficient real and removes that lag.
Derive the magnetic work with the same convention
The average input work rate density is the cycle average of H dB/dt. Substituting the real fields gives
p_mag = (ω/2) μ₀μ″H_pk².
The corresponding cycle energy density is
W_cycle = πμ₀μ″H_pk² = p_mag/f.
The in-phase μ′ contribution integrates to zero over this harmonic cycle; the quadrature loss component supplies the positive net work. Units are W/m³ and J/m³ respectively.
These expressions use peak H. With H_rms = H_pk/√2, the average-power form is p_mag = ωμ₀μ″H_rms². A peak/RMS mismatch creates a factor-of-two error even if the complex sign is correct.
Compare a fictional coefficient and its magnitude
An original illustration sets μ′ = 400, μ″ = 100, H_pk = 100 A/m and f = 50 Hz. The relative permeability is dimensionless and the input field is prescribed.
Its magnitude is 412.310563, loss angle is approximately 14.036° and B_pk is approximately 0.0518125 T. The calculated average magnetic work rate is 197.392 W/m³, with 3.94784 J/m³ per cycle.
Replace μ_r by the purely real number 412.310563 while retaining the same H_pk and frequency. The computed B amplitude remains 0.0518125 T, but its phase lag and the represented magnetic loss both become zero. All of the original model’s magnetic cycle loss has been removed.
The parameters define an assumed linear harmonic material. The replacement comparison holds H fixed. For voltage-driven coupled fields and circuits, recompute the current and field distributions under that boundary condition.

Preserve the loss mechanism boundary
Determine what the imaginary component represents in the source data or effective model. It may summarize particular dissipative mechanisms under its calibration conditions. It is not automatically interchangeable with an explicit conductivity calculation, a fitted total-loss law or an independent hysteresis model.
Keep any separately modeled conductor loss outside this scalar illustration clearly identified. The calculation above establishes only the magnetic work represented by the declared complex relation. It supplies no winding, tank, joint or total-transformer loss.
A favorable match at one frequency also establishes no broadband causal response. Keep the frequency range supported by the data, rather than treating one complex value as an unrestricted transient constitutive law.
Verify the implementation with both amplitude and energy
Retain the signed complex coefficient as entered, its named loss parameter, time convention and peak/RMS basis. Reconstruct the real H and B histories for a simple prescribed-field test, then numerically integrate H dB around a complete cycle.
Check the result against the analytic expression and repeat with finer integration resolution. Compare amplitude, phase and cycle energy separately; a matching amplitude cannot close the other two checks.
Verify the actual model against its directional and operating-condition evidence, then compare the relevant field or circuit outputs independently. Keep the signed coefficient, amplitude, phase and energy checks with that comparison so the permeability’s supported duty is clear.
Calibrate loss phase on a declared harmonic material point
The catalog M-3X limit at 1.7 T and 50 Hz is 0.998694 W/kg. Density 7,650 kg/m³ converts it to 7640.009 W/m³. [1] Assume the scalar harmonic representation above and H_pk = 100 A/m. Matching this power requires μ″ = 2p_mag/(ωμ₀H_pk²) = 3870.474. Matching B_pk = 1.7 T at the same time requires |μᵣ| = 13528.170 and μ′ = 12962.670. The resulting loss angle is 16.625°. These are derived effective coefficients under the stated assumptions; the catalog supplies specific loss and test conditions, not these permeability values. Retain both components when checking the material point.
Retain grade, rolling direction, cutting stress, annealing state, joint flux rotation and clamping condition. An effective permeability fitted to the catalog specimen must be rechecked against the processed core’s relevant direction and excitation before predicting assembly loss. IEC 60404-8-7 provides the delivery-specification framework for fully processed grain-oriented steel. [2]
References
[1] Cleveland-Cliffs, Grain-Oriented Electrical Steels — LITE CARLITE and Mill-Anneal, October 2023, Tables 1 and 5; Stress-Relief Annealing.
[2] IEC, IEC 60404-8-7:2020, Magnetic materials — Part 8-7: Specifications for individual materials — Cold-rolled grain-oriented electrical steel strip and sheet delivered in the fully-processed state.