Record both closing and return branches to qualify split-core seating. Compare local joint position at the same final restraint, and retain the cycle history that changes the required force or recovered geometry.
Calculation basis. Numerical demonstrations use editorial assumptions unless a value is expressly attributed to a cited supplier, standard or published study. Dimensions describe the stated model geometry; test results introduced with “assume” or “suppose” are hypothetical inputs. Calculated outputs inherit those conditions.
A force–displacement loop is useful because it retains the approach and return paths. For a split wound core, the interpretation must separate contact seating, elastic recovery, friction and the measurement fixture itself. The loop is mechanical evidence; its area is not the core’s electrical loss.
Measure motion at the core interface
Define displacement relative to named core datums, with positive motion corresponding to the chosen closing direction. State whether the value represents joint separation, movement of one half or an actuator position. Those coordinates are different.
Actuator travel includes deformation and lost motion in supports, load train and fixtures. In a simple series arrangement, the reported actuator displacement is the sum of core-interface motion and load-train deformation. A correction therefore needs an independently characterized fixture response. If slip, changing contact or rotation occurs in the rig, one constant compliance correction may be inadequate.
Measure force along the intended load path and record alignment. A force sensor does not directly establish a uniform pressure across a cut face. Retain any observed rotation or asymmetric contact that could make a single displacement channel misleading.
Check load-cell indication on loading and unloading against the same force reference. Sensor hysteresis can enter the recorded loop independently of the specimen response. Preserve the transducer direction, calibration and load history.
Preserve both branches and the cycle endpoints
For a proposed development study, retain synchronized force, local displacement and time during approved closing and return motions. Define maximum displacement or force, starting state, rate, dwell and the condition used to end the return. A loop obtained by returning to a small positive force is not directly comparable with one that ends fully released.
Keep the first cycle separate from later cycles. Initial seating may shift a datum or change contact conditions. Later cycles can stabilize, continue drifting or follow another route. Averaging all cycles can hide that distinction.
Record the number and order of cycles, including earlier handling. Do not repeat motion indefinitely until the plot looks consistent: every extra operation changes the specimen’s history. The permitted motion and stop conditions belong to the released design and test fixture.
Interpret recovery without guessing the mechanism
A reversible elastic response retraces its ideal force–displacement relation. Friction, local seating, viscoelastic parts or permanent deformation can create a different return branch. Several mechanisms may coexist, so a loop shape is not a unique diagnosis.
Compare the core datums at the same specified final restraint and observation time. Residual displacement after unloading is different from elastic movement still present under a holding force. Time-dependent recovery in pads or bonding materials can also make an immediate reading differ from a delayed one.
The slope over a chosen unloading interval may provide an apparent stiffness, but it is not necessarily the steel’s Young’s modulus. It combines geometry, contacts and participating support components. Define the interval and verify that the same mechanism is active before using it to compare specimens.
Read loop area as mechanical work
Mechanical work is the path integral of force over the corresponding displacement. For an ideal quasistatic cycle that returns the modeled system to its initial mechanical state, the signed loop integral is the net mechanical work input. If a real specimen has not returned to the same state, changes in stored energy and geometry must also be considered.
A deliberately assumed spring-plus-friction model makes the distinction clear. Let x range from 0 to 1.0 mm in a fixed closing coordinate. Set preload F0 = 100 N, stiffness k = 50 N/mm and opposing friction magnitude Fc = 20 N. During motion, assume:
F_close = F0 + kx + Fc; F_return = F0 + kx − Fc.
At any common x, the branches differ by 40 N. Their closed-loop area is 40 N × 1.0 mm = 40 N·mm = 0.040 J per modeled cycle. The ideal vertical transitions at motion reversal contribute no work because displacement does not change during them.

The 0.040 J is mechanical cycle work under constant friction, linear stiffness, negligible inertia and a repeatable initial/final state. Use the actual seating history for the assembly; assess magnetic loss and permissible stress with their own measurements and criteria.
Combine the loop with the restored-state decision
Use the loop to ask a specific manufacturing question: is a defined closure operation repeatable, does a new fixture alter seating, or does an approved cycle leave a persistent geometric change? Choose the acceptance observable accordingly. Peak force, final gap, residual movement and cycle work are not interchangeable criteria.
Where the mechanical operation could change magnetic response, compare the restored assembly under common electrical conditions. A stable mechanical loop does not prove acceptable loss or excitation. Conversely, an acceptable final magnetic test does not explain a drifting mechanical datum.
Deliver the measured branches, cycle order, local displacement reference, fixture characterization and final core state. Use those records to release a repeatable closure process and verify any changed magnetic response under matched electrical conditions.
Normalize the mechanical cycle without calling it core loss
Nippon Steel lists 23ZH90 at a nominal steel thickness of 0.23 mm and an assumed density of 7.65 kg/dm³. [1] Assume a 100-sheet specimen of 300 × 500 mm steel. Nominal mass is 26.3925 kg. The fictional 0.040 J closure loop therefore represents 0.001516 J/kg per mechanical cycle. At an assumed cycling rate of 0.5 Hz, corresponding mean mechanical work rate is 0.020 W. Retain these units and the actuator boundary; compare magnetic loss only through a separate electrical measurement at its defined induction and frequency. [2]
Manufacturing controls. Control contact pressure, clamp history, closure displacement, rate, sensor hysteresis and final mating geometry. Retain opening and closing branches with the same specimen identity.
References
[1] Nippon Steel Corporation, Grain-Oriented Electrical Steel Sheets, undated, specification tables and annealing compatibility.
[2] M. Pirnat, G. Čepon and M. Boltežar, Introduction of the linear contact model in the dynamic model of laminated structure dynamics: an experimental and numerical identification, 2013, DOI 10.1016/j.mechmachtheory.2013.02.003.