Subsea biofouling adds thermal resistance and changes passage flow. Separate those effects in the temperature model to identify the fouling condition the design can accommodate and monitor. [1]
Calculation basis. Project-specific values and gates in the illustrative screens below are assumptions; cited catalogue values retain their source test conditions.

Separate the conduction and flow hypotheses
Describe assumed coverage, layer thickness and thermal conductivity where conduction through an attached layer is relevant. Independently describe blockage, roughness or geometry changes that affect convection. A patchy layer over an exposed plate is a different boundary from growth that constricts a narrow cooling passage.
| Hypothesis | Model change | Evidence or sensitivity needed |
|---|---|---|
| Uniform attached layer | Added thickness/conductivity resistance | Range of layer thickness and conductivity |
| Patchy coverage | Different local surface resistances | Coverage distribution relative to hot regions |
| Passage obstruction | Changed local velocity and convection | Geometry and flow response, not layer resistance alone |
| Surface roughness change | Possible modification of convection | Applicable correlation or resolved flow analysis |
| Inspection or cleaning strategy | Different assumed condition histories | Access feasibility and verified restored boundary |
Calculate one explicit layer effect
For an illustrative uniform layer, Rlayer = t/(kA). With assumed thickness 2 mm, conductivity 0.2 W/(m·K) and area 20 m², Rlayer = 0.0005 K/W. If all 10 kW crosses that fully covered area, the layer adds 5 K to the modeled temperature difference.
This calculation isolates conduction. It does not include a reduced water-side coefficient caused by blockage, nor does it establish how fast a layer will develop. For partial coverage, heat redistributes through covered and uncovered paths; using the coverage percentage as a direct multiplier on temperature rise may be inadequate.
Convert uncertainty into boundary cases
Study combinations such as clean/open flow, covered/open flow and covered/restricted flow. Preserve consistent loss and seawater-temperature assumptions so that their effects can be compared. Identify whether the critical result comes from layer resistance, loss of usable area or restricted convection.
Do not attach a service year to an assumed thickness without site evidence. Growth varies with location, chemistry, organisms and operating conditions. Maintenance access can also be constrained by the installation architecture, so a promised cleaning interval is not a substitute for a thermal boundary.
The design decision should state which fouling condition can be accommodated and what observation would invalidate that assumption. A clear thickness/coverage/flow sensitivity is more actionable than a universal marine-fouling allowance.
Test layer resistance and restricted flow on the same surface
Continue the assumed 2 mm layer, 0.2 W/(m·K), 20 m² area and 10 kW heat flow above. Thermal resistances in series add [2]. Assume seawater at 20 °C and clean h = 500 W/(m²·K): the water film contributes 0.0001 K/W, giving a 1 K clean external temperature difference. The layer adds 0.0005 K/W, raising that difference to 6 K.
If obstruction reduces the assumed h to 100 W/(m²·K), film resistance becomes 0.0005 K/W. Film plus layer then gives 10 K, or a 30 °C surface in this uniform model. Against an assumed external temperature-difference budget of 8 K, covered/open flow passes and covered/restricted flow fails. Qualify both coverage and flow; neither comparison determines an internal winding hotspot or a growth interval.
References
- IEC/IEEE, IEC/IEEE 61886-2:2025, Subsea equipment — Part 2: Power transformers.
- U.S. Department of Energy, DOE-HDBK-1012/2-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 2, 1992.