B20R070 from 1.50 to 1.80 T: Loss and Magnetizing Data

  • Chenfan Power

The B20R070 query in Chenfan Electric’s CRGO performance tool provides 31 paired loss and magnetizing-capacity values from 1.50 to 1.80 T. Keeping both columns makes the consequence of a higher flux-density selection visible.

CRGO material coils in storage.
Published CRGO material inventory reference; no specific material batch is identified in this photograph.

The complete B20R070 table

B20R070 material data: all 31 source positions
B (T)Specific core loss (W/kg)Magnetizing capacity (VA/kg)
1.500.49230.9664
1.510.49990.9978
1.520.50761.0292
1.530.51521.0605
1.540.52291.0919
1.550.53071.1265
1.560.53931.1681
1.570.54791.2107
1.580.55651.2533
1.590.56511.2959
1.600.5741.3402
1.610.5841.392
1.620.5941.4478
1.630.60381.5074
1.640.61321.5704
1.650.62421.6388
1.660.63541.7134
1.670.64771.7932
1.680.66061.8843
1.690.67321.978
1.700.68692.0804
1.710.70042.1912
1.720.71532.3134
1.730.73182.4577
1.740.74812.6124
1.750.76522.7829
1.760.7832.9666
1.770.80323.1854
1.780.82443.4348
1.790.84713.7287
1.800.87364.1013

At 1.70 T, the table gives 0.6869 W/kg and 2.0804 VA/kg. At 1.80 T, it gives 0.8736 W/kg and 4.1013 VA/kg. Calculated from those points, specific loss rises about 27.2%, while magnetizing capacity rises about 97.1%. The two quantities therefore respond differently across the same interval.

The existing 25-grade directory

B18R060, B20R065, B20R070, B23R080, 23SQGD085, B27R085, B27R090, B27P095, B27R095, B27P100, 27ZH110, 27RGH110, B30P100, 30RK100, 30Q110, 30ZH120, 30Z120, 30QG120, 30RGH120, 30Q120, 30Z130, 30Q130, 30RG130, 30Z140, Z8H-0.3.

The metadata lists loss data for all 25 grades. It flags magnetizing-capacity data as unavailable for 30Z140. This directory identifies available datasets; the complete numerical curve reproduced here is B20R070 only.

Carry the test basis into procurement

For CRGO procurement, specify grade, thickness, coating, frequency and material-test basis. Keep W/kg and VA/kg in their separate fields. The saved query does not establish a batch certificate or verified test frequency; confirm those conditions before comparing another certificate or curve.

These values describe material performance. Finished-core loss also depends on the core geometry, joints, cutting and assembly. Keep the original material table with the enquiry rather than transferring one value into an unrelated finished-core acceptance field.

Chenfan Electric

Direct coordination

Start a conversation.

A drawing, a material requirement, or a project to discuss.

Send drawing