Chenfan Electric
AR
أرسل الرسم
العودة إلى الفيديوهات الهندسية

مكتبة الفيديوهات التقنية

Epstein and Single-Sheet Loss Tests: Compare the Test Basis

المدة 00:57 · 1920 × 1080

ملخص تقني

A specific-loss figure needs its test method, induction and frequency. This video compares the specimen arrangements of an Epstein frame and a single-sheet tester, then follows test records back to the source coil. Sampling, specimen preparation and coating checks form part of the material verification basis.

تنزيل الترجمة النصية

النص الكامل للفيديو
A loss figure needs its test method. An Epstein frame uses strips assembled into a square with overlapping corners. A single sheet tester magnetizes one larger sheet in a yoke. Their results are not directly interchangeable without the applicable method relationship. Record the method, test induction and frequency beside the value. The article uses one point seven tesla at fifty hertz as an example. Define sampling per coil, and prepare specimens to the method's requirements. If coating condition is doubtful, check interlaminar resistance as well. Keep the mill certificate tied to the coil number. Carry that number through slitting, cutting and the core build record. Trace the result back to the steel actually used.

استفسار عن مشروع

تواصل مع فريقنا ↗
Chenfan Electric

تنسيق مباشر

ابدأ التواصل.

رسم أو متطلب مادة أو مشروع ترغب في مناقشته.

أرسل الرسم