Sintesi tecnica

CRGO insulation coating needs protection throughout handling and stacking. This video follows the contact points where scraping, dragging or contaminated surfaces can damage it. It connects handling controls with interlaminar insulation and the condition of the assembled core.

Scarica i sottotitoli

Trascrizione
The insulation between laminations is only a few microns per side. Grain oriented steel normally has a glass film and an insulating coating above it. The outer coating also applies tension to the steel. Handling can damage both functions. Sliding sheets scratches the surface. Impacts, bending, hard debris and dull cutting edges can crack or remove coating. If bare areas touch at separate points, a conducting loop can form between sheets. Damaged areas also lose coating tension and expose steel to moisture. Lift sheets rather than dragging them. Keep stacking surfaces clean, use suitable lifting aids and maintain sharp blades. When coating condition is in doubt, verify interlaminar resistance using the agreed method.