WEBVTT 00:00:00.452 --> 00:00:02.234 Two core quotations need more than 00:00:02.249 --> 00:00:03.155 the same drawing. 00:00:04.009 --> 00:00:05.869 Turn the enquiry into a checkable 00:00:05.884 --> 00:00:06.920 specification. 00:00:07.785 --> 00:00:08.900 Name the steel grade, 00:00:09.009 --> 00:00:11.286 thickness, guaranteed specific loss and 00:00:11.301 --> 00:00:12.168 test method. 00:00:13.019 --> 00:00:14.329 Define the joint pattern, 00:00:14.452 --> 00:00:15.840 step count and overlap. 00:00:16.704 --> 00:00:18.874 Specify burr height and stacking factor, 00:00:18.970 --> 00:00:19.772 then set length, 00:00:19.920 --> 00:00:22.129 angle, width and camber tolerances. 00:00:22.993 --> 00:00:24.762 State the clamping method and whether 00:00:24.777 --> 00:00:26.465 bolts through the limbs are permitted. 00:00:27.316 --> 00:00:29.355 Require coil-traceable certificates, 00:00:29.491 --> 00:00:31.416 incoming test records and the agreed 00:00:31.431 --> 00:00:32.363 final checks. 00:00:33.215 --> 00:00:35.478 Match packing, bracing and monitoring to 00:00:35.493 --> 00:00:36.621 the transport route. 00:00:37.459 --> 00:00:39.512 Every field should connect to material, 00:00:39.595 --> 00:00:41.933 geometry, a measurement or a record. 00:00:42.785 --> 00:00:44.840 Complete the enquiry before comparing the 00:00:44.855 --> 00:00:46.937 prices, so suppliers are quoting the 00:00:46.952 --> 00:00:48.053 same requirements.