WEBVTT 00:00:00.452 --> 00:00:02.130 A loss figure needs its test 00:00:02.145 --> 00:00:02.713 method. 00:00:03.566 --> 00:00:05.817 An Epstein frame uses strips assembled 00:00:05.832 --> 00:00:08.014 into a square with overlapping corners. 00:00:08.879 --> 00:00:11.077 A single sheet tester magnetizes one 00:00:11.092 --> 00:00:12.415 larger sheet in a yoke. 00:00:13.267 --> 00:00:14.853 Their results are not directly 00:00:14.868 --> 00:00:16.780 interchangeable without the applicable 00:00:16.795 --> 00:00:18.014 method relationship. 00:00:18.853 --> 00:00:19.811 Record the method, 00:00:19.933 --> 00:00:22.119 test induction and frequency beside the 00:00:22.134 --> 00:00:22.663 value. 00:00:23.514 --> 00:00:25.374 The article uses one point seven 00:00:25.389 --> 00:00:26.989 tesla at fifty hertz as an 00:00:27.004 --> 00:00:27.702 example. 00:00:28.553 --> 00:00:30.163 Define sampling per coil, 00:00:30.311 --> 00:00:32.080 and prepare specimens to the method's 00:00:32.095 --> 00:00:32.936 requirements. 00:00:33.775 --> 00:00:35.540 If coating condition is doubtful, 00:00:35.702 --> 00:00:37.897 check interlaminar resistance as well. 00:00:38.748 --> 00:00:40.478 Keep the mill certificate tied to 00:00:40.493 --> 00:00:41.426 the coil number. 00:00:42.277 --> 00:00:43.913 Carry that number through slitting, 00:00:44.035 --> 00:00:45.722 cutting and the core build record. 00:00:46.574 --> 00:00:48.004 Trace the result back to the 00:00:48.019 --> 00:00:49.446 steel actually used.