WEBVTT 1 00:00:00.452 --> 00:00:02.377 More tightening is not always better 2 00:00:02.392 --> 00:00:03.845 for a transformer core. 3 00:00:04.712 --> 00:00:06.950 Too little restraint allows laminations and 4 00:00:06.965 --> 00:00:07.949 joints to move. 5 00:00:08.801 --> 00:00:09.707 Too much pressure, 6 00:00:09.816 --> 00:00:10.944 or uneven pressure, 7 00:00:11.014 --> 00:00:12.900 can bend sheets and introduce harmful 8 00:00:12.915 --> 00:00:13.522 stress. 9 00:00:14.373 --> 00:00:15.934 The useful range comes from the 10 00:00:15.949 --> 00:00:16.790 core design. 11 00:00:17.655 --> 00:00:19.840 There is no universal clamping pressure 12 00:00:19.855 --> 00:00:20.853 for every core. 13 00:00:21.717 --> 00:00:23.369 The frame and pressure plates must 14 00:00:23.384 --> 00:00:25.176 spread the load across the packet. 15 00:00:26.027 --> 00:00:27.978 Apply the specified bolt torque or 16 00:00:27.993 --> 00:00:29.889 band tension in the defined sequence, 17 00:00:29.998 --> 00:00:30.996 and keep the record. 18 00:00:31.847 --> 00:00:33.903 Protect the insulation and cut edges 19 00:00:33.918 --> 00:00:34.928 during assembly. 20 00:00:35.780 --> 00:00:37.705 Recheck where the design and process 21 00:00:37.720 --> 00:00:38.509 require it. 22 00:00:39.373 --> 00:00:40.618 The aim is repeatable, 23 00:00:40.715 --> 00:00:42.705 controlled clamping, verified on the 24 00:00:42.720 --> 00:00:43.600 finished core.